Objectif THE THERMAL CAPACITY AND THE COP OF A COMPRESSOR HEAT PUMP CAN BE CONSIDERABLY IMPROVED WHEN INSTEAD OF A PURE FLUID, A FLUID MIXTURE IS USED. CONTRARY TO A PURE FLUID, SUCH A MIXTURE HAS A TEMPERATURE VARIATION DURING THE VAPORIZATION AND CONDENSATION STAGES, WHICH, WHEN PARALLEL TO THE TEMPERATURE CHANGES OF THE FLUID WITH WHICH HEAT EXCHANGE TAKES PLACE, CAN LEAD TO A BETTER HEAT TRANSFER AND TO A HIGHER COP AND/OR THERMAL CAPACITY. THE OBTAINED CAPACITY INCREASE REACHED 28 % FOR WATER-WATER UNITS AND 24 % FOR AIR-WATER UNITS USING A FLUID MIXTURE OF R23 AND R22; THE COP WAS IN THIS CASE ALSO SLIGHTLY IMPROVED. WITH A FLUID MIXTURE OF R12 AND R21 THE COP COULD BE INCREASED BY 10,5 % AS COMPARED TO PURE R21; THE CAPACITY DECREASED SLIGHTLY. A CHOICE WAS MADE FOR THE FURTHER DEVELOPMENT OF HEAT PUMPS WITH R23/R21 MIXTURES WHICH INCREASE THE HEAT CAPACITY. THIS RESULTED IN A COST REDUCTION PER UNIT OF PRODUCED HEAT OF 10 %. ENDURANCE TESTS GAVE VERY GOOD RESULTS AND 20 HEAT PUMPS HAVE BEEN TESTED IN HOUSES DURING THE SEASON 1982/1983. THIS FLUID MIXTURE HEAT PUMP IS NOW BEING COMMERCIALIZED. THIS PROJECT HAS A FOLLOW-UP IN A CEC DEMONSTRATION PROJECT WHERE THE ECONOMIC AND TECHNICAL FEASIBILITY WILL BE DEMONSTRATED. Programme(s) PRE-ENNONUC 2C - Energy research and development programme (EEC), 1979-1983 Thème(s) Data not available Appel à propositions Data not available Régime de financement Data not available Coordinateur Institut Français du Pétrole Contribution de l’UE Aucune donnée Adresse 1-4 avenue du Bois Préau 92506 Rueil-Malmaison France Voir sur la carte Coût total Aucune donnée Participants (1) Trier par ordre alphabétique Trier par contribution de l’UE Tout développer Tout réduire Leroy Somer France Contribution de l’UE Aucune donnée Adresse Moulin de Barillon 16015 Angoulème Voir sur la carte Coût total Aucune donnée