THE PERFORMANCE OF VARIOUS HEATING SYSTEMS IN A MATCHED PAIR OF HOUSES

Ziel



FOUR DIFFERENT HEATING SYSTEMS (OIL FIRED BOILER, CLOSED SOLID FUEL STOVE, SOLID FUEL FIRED BOILER AND HIGH OUTPUT BOILER ON AN OPEN FIRE) HAVE BEEN TESTED AND COMPARED IN A PAIR OF HOUSES. ONE OF THE HOUSES IS A REFERENCE HOUSE WITH ELECTRIC HEATING AND IN THE OTHER HOUSE THE HEATING SYSTEM HAS BEEN TESTED. A COMPUTER HAS BEEN USED FOR DATA COLLECTION AND THE FOLLOWING MEASURING PROGRAMME HAS BEEN CARRIED OUT :

- CALIBRATION AND POSSIBLE MODIFICATION OF THE HOUSES TO ENSURE THAT THEIR THERMAL BEHAVIOUR IS IDENTICAL

- MEASURING THE EFFICIENCY AND ABILITY OF THE FOUR HEATING SYSTEMS TO MEET A VARIETY OF HEATING REGIMES

- IMPROVE THE HEATING SYSTEMS.

THE MEASURED AIR EXCHANGE RATE IN THE TWO HOUSES WAS AROUND 1 VOL/H. EQUIPMENT WAS INSTALLED TO SIMULATE THE HEAT GAINED FROM OCCUPANTS, LIGHTING, CURTAIN DRAWING, COOKING, WATER HEATING, ETC.

/THE FOLLOWING IMPROVEMENTS TO THE HEATINGSYSTEMS HAVE BEEN INTRODUCED: THE INSTALLATION OF A "FIRE FRONT" ON THE OPEN FIRE, FITTING OF THERMOSTATIC VALUES TO ALL RADIATORS AND THE HOT WATER CYLINDER TOGHETHER WITH A FLOW SENSOR TO CONTROL THE PUMP; INTRODUCTION OF A STORAGE BUFFER BETWEEN THE BACK BOILER AND THE DISTRIBUTION SYSTEM.