Skip to main content
European Commission logo print header
Inhalt archiviert am 2022-12-27

SOLAR ELECTRICITY FOR REGIONAL DEVELOPMENT IN CORSICA

Ziel

To illuminate architectural monuments in three remote tourist sites of south-eastern Corsica: a medieval tower, three church ruins and a chapel. Illumination of a map, three planimetries and twelve sign posts with touristical and commercial informations.
The good operation of the installations for the lighting of monuments and the touristic and commercial sign posts gives complete satisfaction to the users.
This project helped in enhancing the historical aspects of the region improving the quality of the services for tourism.
The problems due to robbery and vandalism have unfortunately limited the positive impact expected from this project.
Unit energy cost is reported to be 3.2 ECU/kWh (or 2.9 ECU/kWh for a replication).
Genovese tower on the Pinarellu island: 1620 Wp for three spot light lamps and one inverter,
Tour de Lecci: 1170 Wp for four spot light lamps, (operating since March 92),
Santa Lucia chapel: 450 Wp for three spot light lamps and one inverter,
Touristic and commercial sign posts: 1755 Wp for fluo-lamps; one survey map (270 Wp), three orientation maps (3 x 135 Wp) and twelve touristic sign portes (12 x 90 Wp).
Saite Barbe de Pinarellu: 540 Wp for two spot lights and one inverter, (operating since March 92),
Saite Barbe de Zonza: 540 Wp for two spot lights and one inverter.(operating March 92).
Nr.subsystems : 6
Power subsys. : 1620,1170,450,1755,540,540 Wp
Total power : 5.5 kWp
Backup : none
Nr. of modules : 123
Module descrip. : Photowatt BPX 47 451, 45 W each.
Connection : two in series for all 3 systems, except the 15 small 12V systems.
Support : On racks and on top of the sign posts (horizontal).
Max.pwr.trcker : none
Chrg.controler : Total Energie, TED RC/RD 10000 for the kWp systems, TED/TR1 for the small systems.
Battery : Oldham and STECO
Capacity : 810, 700, 390 and 325 Ah at 24 V
Batt. (Ah) : 150 and 100 Ah at 12 V.
Batt. (kWh) : 1.2 to 19.4 kWh
Inverter : VICTRON, for the fluorescent lamps, and for the sodium high pressure lamps operating at 220 V.
Inv. in (V) : 24 V
Inv. out(V) : 220 V
Inv. power(kW) : 0.6 and 1,2
Load descrpt. : two 100 W, eight 150 W, one 250 W high pressure sodium lamps (Mazda) several 26 W and 35 W low pressure sodium lamps, several 11 and 32 W fluorescent lamps.
Monitoring : two integrating pyranometers, two watthour meters and one hour counter.

Aufforderung zur Vorschlagseinreichung

Data not available

Koordinator

Total Énergie
EU-Beitrag
Keine Daten
Adresse
7 chemin du Plateau
69570 Dardilly
Frankreich

Auf der Karte ansehen

Gesamtkosten
Keine Daten