Abstract

The importance of extrapolating the actual results of outdoor measurements of the electrical characteristics of a photovoltaic array to standard test conditions (STC) is discussed and a practical procedure is proposed. Data obtained at the EnRa facility of the JRC Ispra are used to demonstrate this method for the determination of the STC value of the open-circuit voltage.

Additional information

Authors: BLAESSER G, JRC Ispra Estab. (IT);ROSSI E, JRC Ispra Estab. (IT)
Bibliographic Reference: Article: Solar Cells, Vol. 25 (1988) pp. 91-96