Community Research and Development Information Service - CORDIS

Abstract

A mathematical model and the resultant analytical solutions for calculation of transient tritium concentrations in room air and in solid surfaces are presented. Although more elaborate models exist for describing the behaviour of tritium released into enclosures, a simpler approach was considered adequate for a preliminary assessment of situations arising at JET. A comparison with experimental data and several cases of interest are also presented. These preliminary checks have confirmed that the basic approach is sound. Further checks and refinement may be required to cover the full range of practical situations.

Additional information

Authors: BRERETON S J, JET Joint Undertaking, Abingdon, Oxon. OX14 3EA (GB);GORDON C W, JET Joint Undertaking, Abingdon, Oxon. OX14 3EA (GB)
Bibliographic Reference: Report: JET-R(89)06 EN (1989)
Availability: Available from the Publications Officer, JET Joint Undertaking, Abingdon, Oxon. OX14 3EA (GB)
Record Number: 198911046 / Last updated on: 1994-12-01
Category: PUBLICATION
Original language: en
Available languages: en