The SULTAN-ENEA superconducting magnet is cooled by a large mass flow of liquid helium provided by two pumps. This paper deals with a description of the circulation apparatus as well as with the experience gained in more than 700 hours of operation in the SULTAN Test Facility.

Additional information

Authors: CATITTI A, CENTRO RICERCHE ENERGIA FRASCATI (ITALY);FALCIONI S, CENTRO RICERCHE ENERGIA FRASCATI (ITALY);SPADONI M CENTRO RICERCHE ENERGIA FRASCATI (ITALY), CENTRO RICERCHE ENERGIA FRASCATI (ITALY)
Bibliographic Reference: 2. CONGRESSO NAZIONALE DI CRIOGENIA TORINO (ITALY), FEB 8-9, 1984 WRITE TO ENEA - SERVIZIO STUDI E DOCUMENTATIONE, CENTRO RICERCHE ENERGIA FRASCATI, C.P 65 00044 FRASCATI, ROMA (ITALY) MENTIONING REPORT 84.5/CC, 1984 - PP. 21-26