Community Research and Development Information Service - CORDIS

Abstract

TFR has been operated in low-q(a) conditions, with a special emphasis on the understanding of the so-called current limit. Several schemes have been used, one of the most promising being magnetic surface skinning with a variable toroidal field. A detailed analysis of Mirnov coil and soft X-ray signals is presented and the results are discussed.

Additional information

Authors: TFR GROUP CEA, FONTENAY-AUX-ROSES (FRANCE), CEA, FONTENAY-AUX-ROSES (FRANCE)
Bibliographic Reference: NUCLEAR FUSION, VOL. 24 (1984) NO. 6, PP. 784-788
Record Number: 1989123012200 / Last updated on: 1987-01-01
Category: PUBLICATION
Available languages: en