Abstract

A graphics display system was developed to show measured liquid collapsed and mixture levels in the LOBI MOD2 experimental blowdown facility during small break tests. The paper describes the algorithms and hardware of this system, geometries and operational experience during the small break tests of 1984. In addition first results of a new collapsed level measurement over the cross section of the horizontal loop pipe (46 mm diameter) are shown.

Additional information

Authors: SANDERS J, BATTELLE INSTITUT E.V., FRANKFURT (GERMANY);JRC ISPRA ESTAB. (ITALY);WITTEBROOD B, BATTELLE INSTITUT E.V., FRANKFURT (GERMANY);JRC ISPRA ESTAB. (ITALY);EDER J, BATTELLE INSTITUT E.V., FRANKFURT (GERMANY);JRC ISPRA ESTAB. (ITALY);OHLMER E BATTELLE INSTITUT E.V., FRANKFURT (GERMANY), BATTELLE INSTITUT E.V., FRANKFURT (GERMANY);JRC ISPRA ESTAB. (ITALY);JRC ISPRA ESTAB. (ITALY), BATTELLE INSTITUT E.V., FRANKFURT (GERMANY);JRC ISPRA ESTAB. (ITALY)
Bibliographic Reference: SPECIALISTS MEETING ON SMALL BREAK LOCA ANALYSIS IN LWRS, PISA (ITALY), JUNE 23-27, 1985 WRITE TO CEC LUXEMBOURG, DG XIII/A2, POB 1907 MENTIONING PAPER E 32092 ORA