Community Research and Development Information Service - CORDIS

Abstract

The behaviour of the plasma in the EXTRAP device was found to differ drastically from the conventional Z-pinch discharges. The comparative discussion on the properties of these two configurations is presented. It is shown that the energy loss mechanism is responsible for the arising difference between them. Given the lack of experiment data on the confinement of the peripheral plasma, in the present study we suggest a scaling for the net energy loss with plasma density and temperature. Using self-similar methods, we show that strongly non- linear damped oscillations arise as a result of our scaling. Some preliminary results on stability of this system are reported. Finally, some technical recommendations for the design of the toroidal device EXTRAP-T1 are put forward. In particular the scheme, allowing extension of the pulse duration, which is rather limited in the present version, is suggested.

Additional information

Authors: TENDLER M ROYAL INSTITUTE OF TECHNOLOGY, STOCKHOLM (SWEDEN), ROYAL INSTITUTE OF TECHNOLOGY, STOCKHOLM (SWEDEN)
Bibliographic Reference: WRITE TO THE DEPARTMENT OF PLASMA PHYSICS AND FUSION RESEARCH, ROYAL INSTITUTE OF TECHNOLOGY, S-100 44 STOCKHOLM (SWEDEN) MENTIONING REPORT TRITA-PFU-86-04, 1986
Record Number: 1989124095800 / Last updated on: 1987-01-01
Category: PUBLICATION
Available languages: en