Two antennae have been installed in JET and operated to the maximum design capability of the generators. 4.5 MW, 10MJ have been coupled to the plasma which heated up to a maximum stopped energy of 3 MJ with central temperatures of T-eO = keV and T-iO = keV without increase of the relative impurity concentration. Degradation of energy confinement is observed according to an L mode scaling. The effect of k-// shaping is discussed using a quadrupole antenna. Hydrogen and Helium 3 minority heating regimes give similar results.

Additional information

Authors: JACQUINOT J JET JOINT UNDERTAKING, ABINGDON (UK), JET JOINT UNDERTAKING, ABINGDON (UK)
Bibliographic Reference: WRITE TO THE PUBLICATIONS OFFICER, JET JOINT UNDERTAKING, ABINGDON, OXON, OX14 3EA (UK), MENTIONING REPORT JET-P(85)20, 1985
Record Number: 1989124099800 / Last updated on: 1987-01-01