Community Research and Development Information Service - CORDIS

Abstract

The CONT benchmark calculation exercise is a project sponsored by the Containment Loading and Response Group, a subgroup of the Safety Working Group of the Fast Reactor Coordinating Committee + CEC. A full size typical Pool type LMFBR undergoing a postulated Core Disruptive Accident (CDA) has been defined by Belgonucleaire-Brussels under a study contract financed by the CEC and has been submitted to seven containment code calculations. The results of these calculations are presented and discussed in this paper.

Additional information

Authors: BENUZZI A JRC ISPRA ESTAB. (ITALY), JRC ISPRA ESTAB. (ITALY)
Bibliographic Reference: EUR 10638 EN (1986) MF, 38 P., BFR 150, BLOW-UP COPY BFR 200, EUROFFICE, LUXEMBOURG, POB 1003
Availability: Can be ordered online
Record Number: 1989125017400 / Last updated on: 1987-02-01
Category: PUBLICATION
Available languages: en
Follow us on: RSS Facebook Twitter YouTube Managed by the EU Publications Office Top