Abstract

Within PISC II a parametric study has been performed aiming to evaluate the effect of a large number of variable parameters of a UT testing system. Probe parameters, cable parameters and instrument parameters have individually been analysed and their effect on detection location and sizing of defect are discussed.

Additional information

Authors: LAKESTANI F, JRC ISPRA ESTAB. (ITALY);BORLOO E, JRC ISPRA ESTAB. (ITALY);MERLI F JRC ISPRA ESTAB. (ITALY), JRC ISPRA ESTAB. (ITALY)
Bibliographic Reference: SMIRT POST CONFERENCE SEMINAR NO. 3, DAVOS (SWITZERLAND), AUG. 24-28, 1987 WRITE TO CEC LUXEMBOURG, DG XIII/A2, POB 1907 MENTIONING PAPER E 33407 ORA
Availability: Can be ordered online
Record Number: 1989126023501 / Last updated on: 1989-01-01