Community Research and Development Information Service - CORDIS

Abstract

Parametric calculations of the evacuation process were carried out for the NET-vacuum chamber involving two blanket designs. The results show that with an acceptable vacuum pumping capacity the required start vacuum conditions can be realized within reasonable time. The two blanket concepts do not differ remarkably in their evacuation behaviour. The remaining large pressure differences between the different locations of the vacuum chamber can be reduced if approximately 30% of the total gas flow is extracted from the heads of the blanket replacement ports.

Additional information

Authors: MUELLER R A KERNFORSCHUNGSZENTRUM KARLSRUHE (GERMANY), KERNFORSCHUNGSZENTRUM KARLSRUHE (GERMANY)
Bibliographic Reference: 14TH SOFT CONFERENCE, AVIGNON (FRANCE), SEPT. 8-12, 1986 VOL. 1, PP. 527-532 1895 P., 1986, VOL. 1 AND VOL. 2, ISBN 0 08 034935 8 WRITE TO PERGAMON PRESS, HEADINGTON HILL HALL, OXFORD, OX3 0BW (UK), PRICE: UKL 220 (FOR BOTH VOLS.)
Record Number: 1989126043401 / Last updated on: 1989-01-01
Category: PUBLICATION
Available languages: en