The optical and electronic design of the Thomson scattering experiment in the ASDEX-Tokamak is described. This Thomson scattering system is employed as a standard diagnostic for the evaluation of electron temperature and density simultaneously at 16 spatial points in ASDEX. The light source is a Nd-YAG laser emitting at 1.06 mum wavelength, which is capable of delivering 60 pulses per second for a period of about 7 sec. This period includes the whole ASDEX plasma discharge. The scattered light is detected by Si-avalanche diodes. Density calibration is carried out by rotational anti-Stokes Raman scattering from molecular hydrogen. The system is capable of measuring densities as low as 5 x 1012 cm-3 and electron temperatures in the range from 150 eV to 5 keV. The data-processing system and the calculations which lead to the final output of Te/Ne-profiles are discussed. Examples of profile measurements are given showing the possibilities of the system under various plasma conditions.

Additional information

Authors: ROEHR H, MAX-PLANCK-INSTITUT FUER PLASMAPHYSIK, GARCHING BEI MUENCHEN (GERMANY);STEUER K H, MAX-PLANCK-INSTITUT FUER PLASMAPHYSIK, GARCHING BEI MUENCHEN (GERMANY);MURMANN H, MAX-PLANCK-INSTITUT FUER PLASMAPHYSIK, GARCHING BEI MUENCHEN (GERMANY);MEISEL D MAX-PLANCK-INSTITUT FUER PLASMAPHYSIK, GARCHING BEI MUENCHEN (GERMANY), MAX-PLANCK-INSTITUT FUER PLASMAPHYSIK, GARCHING BEI MUENCHEN (GERMANY)