Community Research and Development Information Service - CORDIS

Abstract

This report describes the certification of a reference material for the determination of Cr, Fe, Hf and Sn in Zircaloy-4. The material is available in the form of chips and has been analysed in 16 laboratories using a wide range of techniques. No inhomogeneity within or between the bottles of chips could be detected. The following contents (mass fraction) are certified: item"" Cr : (906 pm 9) mug/g item"" Fe : (2.143 pm 0.020) mg/g item"" Hf : (77.6 pm 3.0) mug/g item"" Sn : (14.60 pm 0.09) mg/gpar

Additional information

Authors: VANDENDRIESSCHE S, CEC, BRUXELLES (BELGIUM);GRIEPINK B CEC, BRUXELLES (BELGIUM), CEC, BRUXELLES (BELGIUM)
Bibliographic Reference: EUR 11579 EN, (1988) FS, 22 PP., ECU 5.00, AVAILABILITY: EUROFFICE, LUXEMBOURG, POB 1003
Availability: Can be ordered online
Record Number: 1989126103700 / Last updated on: 1989-06-01
Category: PUBLICATION