Community Research and Development Information Service - CORDIS

Abstract

IN ORDER TO INCREASE THE MAXIMUM FLUX SWEEP, A PRESENT TREND IS TO DESIGN OHMIC COILS PRODUCING FIELDS AS HIGH AS 11 TESLAS. IN NIOBIUM TITANIUM, CRITICAL CURRENT DENSITIES OF 10 E9 A/M2 AT 1.8K UNDER A FIELD OF 11 TESLAS IS NOW CLAIMED BY SEVERAL MANUFACTURERS. THIS IN ADDITION ENABLES ONE TO MAKE USE OF THE OUTSTANDING COOLING PROPERTIES OF HE II. THE FORCED FLOW TECHNIQUE CAN AGAIN BE ENVISAGED FOR HE II TO REMOVE THE HEAT LOAD. TWO SOLUTIONS ARE INVESTIGATED. THE FIRST ONE USES A 40KA CABLE WOUND IN A CABLE WOUND IN DOUBLE PANCAKES. THE SECOND ONE MAKES USE OF SEVERAL CONDUCTORS LAYER WOUND AND CURRENT SUPPLIED IN PARALLEL.

Additional information

Authors: CIAZYNSKI D, CEA, CEN, F;TURCK B, CEA, CEN, F;DUCHATEAU J L CEA, CEN, F, CEA, CEN, F
Bibliographic Reference: PAPER PRESENTED: TENTH INTERNATIONAL CONFERENCE ON MAGNET TERMINOLOGY (MT10), BOSTON/USA, SEPT. 22-25, 1987, AVAILABILITY: CEC-LUXEMBOURG, DG XIII/A2, BP 1907, MENTIONING PAPER ORA 33603 E
Availability: Can be ordered online
Record Number: 1989126220100 / Last updated on: 1989-04-01
Category: PUBLICATION
Available languages: en