Community Research and Development Information Service - CORDIS

Abstract

This report gives a review of proposed measurement techniques to measure quantitatively the release and transport of fission products during and after fission product release tests. The measurement devices considered include gamma-spectrometers, scintillation counters and sampling vessels. The second part of the report reviews the behaviour of fission product iodine under severe accident conditions and describes the iodine sampling system and the determination of iodine species in aequeous solutions.

Additional information

Authors: SCHUSTER E, SIEMENS A.G., ERLANGEN (DE);NOPITSCH K SIEMENS A.G., ERLANGEN (DE), SIEMENS A.G., ERLANGEN (DE)
Bibliographic Reference: EUR 12398 EN (1989) 52 PP., FS, ECU 5 THE OFFICE FOR OFFICIAL PUBLICATIONS OF THE EUROPEAN COMMUNITIES, L-2985 LUXEMBOURG
Record Number: 1989128029200 / Last updated on: 1991-05-15
Category: PUBLICATION
Original language: EN