This document is the collection of the individual reports of the laboratories which participated in the intercomparison campaign. A synthesis report is published full size with the same title (EUR 10101). This report describes the first international intercomparison of high attenuation measurements up to 100 dB at 30 MHz. Participants were the IENGF, LCIE, NPL, VSL and the PTB. Three standard attenuators were circulated: one of 60 dB and two of 100 dB, developed by the PTB. The two measurement methods used were the RF parallel substitution method with national standard attenuators (IEN, LCIE, NPL, VSL) and the power ratio method with a chain of precise GR 900 coaxial attenuators in cascade (PTB). All measurement results agreed within +/- 0.016 dB for the 60 dB transfer attenuator and within +/- 0.07 dB for the 100 dB attenuators. In the best cases the differences between the laboratories were 0.001 dB for the 60 dB device and +/- 0.005 dB for the 100 dB attenuators.

Additional information

Authors: BAYER H, Physikalisch Technische Bundesanstalt, Braunschweig (DE);GRIT J H, Van Swinden Laboratorium, Delft (NL);YELL R W, National Physical Laboratory, Teddington (GB);ERARD L, Laboratoire Central des Industries Electriques, Fontenay-aux-Roses (FR);GALLIANO P G, Istituto Elettrotecnico Nazionale Galileo Ferraris, Torino (IT)
Bibliographic Reference: EUR 12973 EN (1990) 136 pp., MF, ECU 8
Availability: (2)
Record Number: 199011079 / Last updated on: 1994-12-01
Category: PUBLICATION
Original language: en
Available languages: en