Abstract

The objective is the "on site" study of the influence of an injection screen on the flow in a water table of a porous medium, in order to improve the safety of a surface radioactive waste storage site. A hydrodispersive study has provided information for the definition of the role of the screen: the transfer times of the pollutant in the water table are increased by a factor of 2 and, in comparison, the concentrations are clearly reduced by a factor of 10. The implantation of an injection screen in the ground should result in an improvement in the restrictive quality of the barrier and the contamination of an aquifer should be slower without interruption to the flow.

Additional information

Authors: GROS J-C, CEA-CEN-FAR, Fontenay-aux-Roses (FR);MADOZ-ESCANDE C, CEA-CEN-FAR, Fontenay-aux-Roses (FR);METIVIER J-M, CEA-CEN-FAR, Fontenay-aux-Roses (FR);GRIMAUD P, CEA-CEN-FAR, Fontenay-aux-Roses (FR)
Bibliographic Reference: EUR 12838 FR (1990) 30 pp., FS, ECU 5