Community Research and Development Information Service - CORDIS

Abstract

The test data for the 100 and 250 mm EEC orifice plate project were assessed and discussed with the staff at each of the facilities involved. Reasons for the differences between the results were identified in most instances, so that agreement to within 0.4% could be found for the 250 mm data and to within 0.3% for the 100 mm data.

Additional information

Authors: KINGHORN F, National Engineering Laboratory, Glasgow (GB)
Bibliographic Reference: EUR 13724 EN (1991) 48 pp., MF, ECU 4
Availability: (2)
Record Number: 199110967 / Last updated on: 1994-12-02
Category: PUBLICATION
Original language: en
Available languages: en