Community Research and Development Information Service - CORDIS

Abstract

This paper compares C(44) elastic constant data measured for UO(2) at different temperatures using the inelastic neutron scattering technique and ultrasonics. The measurements confirm the C(44) softening between room temperature and the Néel temperature. This can be observed from the results obtained using both ultrasonics and neutron scattering. It is noted that the ultrasonic values are approximately 14% lower than the neutron derived values. The ultrasonic results are in good agreement with previous ultrasonic measurements of C(44) at room temperature.

Additional information

Authors: DU PLESSIS P DE V, Rand Afrikaans University, Department of Physics, Johannesburg (ZA);LANDER G H, JRC Karlsruhe (DE);STRYDOM A M, AEC of South Africa Ltd., Pretoria (ZA);FÄK B, Institut Laue-Langevin, Grenoble (FR);FAK B, Institut Laue-Langevin, Grenoble (FR)
Bibliographic Reference: Paper presented: International Conference on Neutron Scattering, Oxford (GB), Aug. 27-30, 1991
Availability: Available from (1) as Paper EN 36402 ORA
Record Number: 199111453 / Last updated on: 1994-12-02
Category: PUBLICATION
Original language: en
Available languages: en