Community Research and Development Information Service - CORDIS

Abstract

The report describes the determination of the discharge coefficients of a 600 mm diameter orifice plate meter in natural gas under ideal conditions using orifice plate beta ratios of 0.2, 0.37, 0.5, 0.57, 0.66 and 0.75. These measurements form part of a larger series conducted in one other natural gas facility and two water facilities.

Additional information

Authors: N V GASUNIE, N V Gasunie, Groningen (NL)
Bibliographic Reference: EUR 14094 EN (1992) 952 pp., MF, ECU 40
Availability: (2)
Record Number: 199210921 / Last updated on: 1994-12-02
Category: PUBLICATION
Original language: en
Available languages: en