Measurements of the ion and electron temperature and density in an electron cyclotron discharge, by means of the rotatable double probe and a retarding field analyser, are presented. A significant resonance absorption at the second harmonic was observed. A discussion of the relevance of the results for the optimum operation of such a discharge as an ion source follows.

Additional information

Authors: HÖTHKER K, Kernforschungsanlage Jülich GmbH, Institut für Plasmaphysik, Jülich (DE);BELITZ H J, Kernforschungsanlage Jülich GmbH, Institut für Plasmaphysik, Jülich (DE);AMEMIYA H, RIKEN, Wako-shi, Hirosawa, Saitama (JP);OYAMA H, RIKEN, Wako-shi, Hirosawa, Saitama (JP);YANO K, RIKEN, Wako-shi, Hirosawa, Saitama (JP);BIEGER W, Fachhochschule Aachen, Abt. Jülich (DE);SHIGUEOKA Y, University of Amazon, Manaus (BR);HOTHKER K, Kernforschungsanlage Julich GmbH, Institut fur Plasmaphysik, Julich (DE)
Bibliographic Reference: Article: Nuclear Instruments and Methods in Physics Research B, Vol. 63 (1992) pp. 484-488
Record Number: 199211075 / Last updated on: 1994-11-29