Abstract

A series of activation and fission monitor materials for reactor dosimetry has been prepared. High purity metals were analysed for trace impurities that may cause spectral or direct nuclear interference during use. Alloy homogeneity on a 10 to 20 mg scale, representative of the sample size used for dosimetry, was investigated. Analyses were performed by specialist European laboratories and certification was approved by the EC Nuclear Certification Group.

Additional information

Authors: INGELBRECHT C, JRC Geel (BE);PAUWELS J, JRC Geel (BE)
Bibliographic Reference: Paper presented: International k(0) Users Conference, Astene (BE), September 29 - October 1, 1992
Availability: Available from (1) as Paper EN 37198