Abstract

Experimental data are presented for top-venting of flashing high-viscosity fluids. In addition, a practical vent-sizing method is described which is applicable to such problems. The method employs a viscosity factor which is correlated to the experimental data for fluids with viscosities ranging up to 750 cP at initial conditions. Although principally aimed at venting of non-reacting vapour pressure systems, this work is of interest also for chemically reacting systems.

Additional information

Authors: MORRIS S D, JRC Ispra (IT);BELL K, JRC Ispra (IT);OSTER R, JRC Ispra (IT)
Bibliographic Reference: Article: Chemical Engineering and Processing, Vol. 31 (1992), pp. 297-305