The K(ow) values of 39 chlorobiphenyl congeners were determined simultaneously in a PCB mixture, Askarel, using a modified generator column method and congener specific analysis by GC-ECD with narrow-bore capillary columns. The log K(ow) values ranged from 5.18 for dichlorobiphenyls to 7.07 for octachlorobiphenyls with a standard deviation between 0.01 and 0.24. These values were in agreement with data obtained from individual congener measurements as well as with available literature based upon generator column experiments.

Additional information

Authors: LARSEN B, JRC Ispra (IT);SKEJO-ANDREASEN H, JRC Ispra (IT);PAYA-PEREZ A, JRC Ispra (IT)
Bibliographic Reference: Article: Fresenius' Environmental Bulletin, Vol. 1/Supplementum (1992) pp. S13-S18