Community Research and Development Information Service - CORDIS

Abstract

Steels containing (wt. %) 0.25 - 1.6 Si, 0.03 - 1.0 Al, 0 - 13 Cr and 0 - 0.3 Cu were tested with regard to uniform corrosion attack in the immersion, tidal and splash zones off Helgoland and on land-mounted racks exposed to marine, rural and urban air, as well as with regard to stress-corrosion cracking in seawater. In the latter tests the immersion zone off Helgoland and a 30 bar pressure vessel were used. The test pieces were exposed both to free corrosion and to cathodic protection afforded by zinc anodes.

Additional information

Authors: DRODTEN P, Thyssen Stahl AG, Duisburg (DE);SCHWENK W, Mannesmann-Forschungsinstitut GmbH, Duisburg (DE);GRIMME D, Verein Deutscher Eisenhüttenleute, Düsseldorf (DE);HAUMANN W, Hoesch Stahl AG, Dortmund (DE)
Bibliographic Reference: EUR 14333 DE (1993) 29 pp., FS, ECU 7
Availability: (2)
ISBN: ISBN 92-826-5956-9
Record Number: 199310796 / Last updated on: 1994-11-29
Category: PUBLICATION
Original language: de
Available languages: de