The aim of this work is to investigate the possible use of commercial adsorbents such as 3A molecular sieves, zeolites of the mordenite family and silica-gel as passive samplers to monitor HTO concentration in air for long periods of time. The water adsorption properties of these materials and the effects of the sampler geometry on water sorption rate are evaluated and discussed.