Abstract

Endoscopic probes using digital speckle pattern interferometry (DSPI) have geometrical constraints which reduce the fringe quality of the images. Two experimental arrangements are presented for real-time interferometric inspection of internal parts of objects. Image processing techniques are applied to endoscopic fringes for speckle noise reduction and fringe contrast enhancement.

Additional information

Authors: FACCHINI M, JRC Ispra (IT);ZANETTA P, JRC Ispra (IT);ALBRECHT D, JRC Ispra (IT)
Bibliographic Reference: Paper presented: Fringe '93 - 2nd International Workshop on Automatic Processing of Fringe Patterns, Bremen (DE), October 19-21, 1993
Availability: Available from (1) as Paper EN 37870 ORA