Abstract

For this validation exercise, models predicting the amplitude of the ultrasonic echoes as a function of probe position have been chosen. Three of the models had provided an example of prediction for specific defects in the inspection of steel components, and these are considered in this report. The results of the models are compared with experimental observations, and the situations identified in which the models work well or fail. In particular, further work is needed for defects having curved edges and for near-surface defects.

Additional information

Authors: LAKESTANI F, JRC Petten (NL)
Bibliographic Reference: EUR 14673 EN (1992) 44 pp., FS, free of charge
Availability: Available from Joint Research Centre, Publication Department, I-21020 Ispra (Va.) (IT)
Record Number: 199511017 / Last updated on: 1995-08-18