Abstract

From October 1993 to April 1994 the ETHEL calorimeter was made available to TLK for active tritium measurements on four portable getter beds of Amersham design, with tritium inventories ranging from 1 to 23 kCi. The calorimeter was calibrated using an electrical heat source with a high degree of simulation to the active getter bed. Error analysis revealed a negative bias of about 3 mW over the whole range measured. Tritium inventory measurements could be reproduced with an absolute standard deviation of less than 30 Ci which is equivalent to 1 mW, independent of the actual tritium inventory of the getter bed.

Additional information

Authors: KRAEMER R, Forschungszentrum Karlsruhe, Tritiumlabor Karlsruhe (TLK) (DE);THORNTON M I, JRC Ispra (IT)
Bibliographic Reference: Paper presented: ESARDA 17th Annual Symposium on Safeguards and Nuclear Material Management, Aachen (DE), May 9-11, 1995
Availability: Available from (1) as Paper EN 39048 ORA
Record Number: 199511078 / Last updated on: 1995-08-18
Category: PUBLICATION
Original language: en
Available languages: en