Simulations of the accuracy of laser-flash data analysis methods show that thermal diffusivity can be recovered at an accuracy of 2 % and that the noise in the waveform recorded has a near 1 to 1 relationship with the data for the choice of parameters. An estimate of accuracy of measurements obtained on the in-house system can be directly deduced by observing the noise level on the experimental waveform. A slight upward shift of values, worse at 3000 K than 300 K and worse with increasing noise amplitude and loss, needs further investigation.