Assembly no. 24 was a precise copy of a real nozzle and safe-end of the Caorso (Italy) BWR pressure vessel. The flaws introduced in the safe-end area included semi-elliptical flaws with sharp crack edges and smooth surfaces, introduced by particular machining or as implants containing these flaws. The evaluation of the techniques used to detect these flaws showed that some techniques are capable of high detection but that the overall performance given by a full procedure is generally not obtained by a simple technique.

Additional information

Authors: PISC, JRC Ispra (IT)
Bibliographic Reference: EUR 15369 EN (1993) 57 pp., FS, free of charge
Availability: Available from Joint Research Centre, Publication Department, I-21020 Ispra (Va.) (IT)
Record Number: 199511588 / Last updated on: 1995-12-12
Category: PUBLICATION
Original language: en
Available languages: en