Performance values are reported of different active neutron interrogation techniques for the assay of the fissile content, (ie (235)U), in uranium material. The techniques discussed are the neutron coincidence collar (NCC), active well coincidence counter (AWCC), Phonid and advanced Phonid techniques, based on a combination of emission and transmission measurements. Most of the results are based on measurements of well characterized PERLA standards and discussed in terms of in-field applications.

Additional information

Authors: CLAPHAM M, BNLF Instruments Ltd, Calderbridge (GB);FARESE N, JRC Ispra (IT);JAIME R, JRC Ispra (IT);LEZZOLI L, JRC Ispra (IT);SCHILLEBEECKX P, JRC Ispra (IT)
Bibliographic Reference: Paper presented: 19th Annual Symposium on Safeguards and Nuclear Material Management, Montpellier (FR), May 13-15, 1997
Availability: Available from (1) as Paper EN 40557 ORA
Record Number: 199710854 / Last updated on: 1997-07-08
Original language: en
Available languages: en