Community Research and Development Information Service - CORDIS

Abstract

This paper described an approach to define a stable reference device for the measurement and monitoring of a Si-modules. The device is based on a crystalline silicon cell identical in construction to an ESTI Sensor with the addition of a broad band filter to match the spectral response of the device to that of a-Si. The calibration procedure is described generically and uncertainties regarding statistical evaluation are highlighted together with the spectral response of the device. Different calibration factors are obtained depending upon the reference device used. Device performance over an 18 month period is compared to that of a normal ESTI sensor.

Additional information

Authors: DUNLOP E D, ASIC Services, Ayr (GB);ZAAIMAN W, JRC Ispra (IT);OSSENBRINK H A, JRC Ispra (IT);HELMKE C, JRC Ispra (IT)
Bibliographic Reference: Paper presented: 14th European Photovoltaic Solar Energy Conference & Exhibition, Barcelona (ES), June 30-July 4, 1997
Availability: Available from (1) as Paper EN 40754 ORA
Record Number: 199711101 / Last updated on: 1997-09-16
Category: PUBLICATION
Original language: en
Available languages: en