In the course of the certification campaign of a future mixed oxide (MOX) reference material, non-destructive measurements were performed to obtain information on homogeneity of isotopic ratios of Pu and Am isotopes and homogeneity of the U/Pu ratio. For this purpose gamma spectrometry in combination with the MGA code for spectra evaluation was used. Precision is not as low as obtainable by destructive analysis, however a rapid and fairly precise overview is achieved which would easily detect gross deviations.