Community Research and Development Information Service - CORDIS

Abstract

The objective of Action 5 of PISC III is the experimental evaluation of the performance of test procedures and techniques in use for steam generator tubes in nuclear power plants during in-service inspection. The Blind Test Tubes of the Round Robin Test (RRT) were circulated to 29 participating organizations of 9 different countries. Data and capability of in-service inspection (ISI) techniques, which are evaluated in this paper, indicate that there was a wide dispersion of detection of sizing performance.

Additional information

Authors: BIETH M, JRC Petten (NL);BIRAC C, Electricité de France, Saint-Denis (FR);COMBY R, Electricité de France, Saint-Denis (FR);MACIGA G, ENEL, DCO, Piacenza (IT)
Bibliographic Reference: Paper presented: 7th European Conference on Non-Destructive Testing, Copenhagen (DK), May 27-29, 1998
Availability: Available from (1) as Paper EN 41728 ORA
Record Number: 199811253 / Last updated on: 1998-10-27
Category: PUBLICATION
Original language: en
Available languages: en