A number of pressure drop measurements have been carried out at CRPP on a section of ITER cable-in-conduit conductor, using pressurised water at room temperature. The longitudinal friction factor is deduced for the strand bundle area and the central hole. Two layouts of radial helium inlet have been investigated and the measured radial pressure drop is assessed in terms of the equivalent conductor length producing the same pressure drop in axial direction.

Additional information

Authors: BRUZZONE P, CRPP-Technologies de la Fusion, Villigen (CH)
Bibliographic Reference: An article published in: Fusion Engineering and Design 58-59 (2001) pp. 211-215
Record Number: 200214424 / Last updated on: 2002-02-20