In the year 2000, a new version of the analog integrator used in Tore Supra for magnetic measurements has been designed. Although based on the same principles, this new integrator was improved in order to satisfy the new long duration of pulses, up to 1000 s, expected in near future on Tore Supra. After recalling the basic principles of the analog integrators and recent improvements, this article explains the main characteristics of the new integrators, tests and obtained results. The conclusion underlines the most important results and, in particular, the capability of the new integrator to answer to the International thermonuclear experimental reactor (ITER) requirements.

Additional information

Authors: SPUIG P ET AL, Association Euratom-CEA, Département de Recherches sur la Fusion Contrôlée, CEA/DSM/DRFC, CEA/Cadarache, Saint Paul Lez Durance (FR)
Bibliographic Reference: An article published in: Fusion Engineering and Design, Volumes 66-68, September 2003, Pages 953-957 (22nd Symposium on Fusion Technology)
Availability: This article can be accessed online by subscribers, and can be ordered online by non-subscribers, at:
Record Number: 200316997 / Last updated on: 2003-10-23
Original language: en
Available languages: en