Wspólnotowy Serwis Informacyjny Badan i Rozwoju - CORDIS

FP5

REGENCATS Streszczenie raportu

Project ID: G5RD-CT-2000-00376
Źródło dofinansowania: FP5-GROWTH
Kraj: Sweden

Thermical treatments in gas flows

The thermal treatment of TWC has shown a reactivation in the catalytic activity during the development of the studies. The thermal treatment has removed the organic poison from the TWC providing an increment in the life cycle of the TWC. The application of the process could be used with many other catalytic system, which involve organic matter: The deposits of this organic matter will deactivate the catalytic surface but this could be recovered by applying the thermal treatment. This procedure has proven to be successful using the methods described:
- Oxygen treatment at 500 to 700ºC.
- Chlorine (0.5-5%)/Oxygen treatment at 300ºC.
- Chlorine (<1%)/Oxygen treatment at 500ºC.
- Hydrochloric acid pre treatment at 300-500ºC.

Powiązane informacje

Reported by

KTH
Teknikringen 42
100 44 Stockholm
Sweden
See on map
Śledź nas na: RSS Facebook Twitter YouTube Zarządzany przez Urząd Publikacji UE W górę