{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"151802","id":"151802-breathe-easy-with-a-synthetic-lung","title":"Breathe easy with a synthetic lung","teaser":"A revolutionary new artificial lung promises to significantly increase the quality of life and life expectancy of the millions of people suffering from chronic obstructive pulmonary disease (COPD).","body":"\u003Csection\u003E\u003CsectionBody\u003ECurrently available artificial lungs typically fail after approximately one month, leaving COPD as the fourth leading cause of death worldwide. Scientists on the EU-funded project http:\/\/www.ambulung.com\/home\/ (AMBULUNG) (Ambulatory bio-artificial lung) have delivered a first-of-its-kind wearable, ambulatory bio-artificial lung for long-term outpatient use.\n\nThe effective use of commercial lung assist systems is limited by thrombus formation at the blood-machine interface. Moreover, bulkiness also restricts their use to the Intensive Care Unit. To limit thrombus formation, increased gas exchange rate and the service life of the gas exchange unit, researchers worked to integrate human endothelial cells (ECs) into the diffusion membrane. Another key focus area was miniaturisation of the device to increase patient mobility, and facilitate use in an outpatient setting.\n\nProject members developed suitable processes to differentiate ECs from human embryonic stem cells and expanded these ECs to ensure adequate numbers for cellularisation of the diffusion membrane. In parallel, they functionalised the gas-exchange surface of the diffusion membrane using biochemical and physical methods to ensure favourable conditions for cellularisation. Via seeding tests using a newly developed dynamic bioreactor, they also determined optimal surface conditions required to promote a durable and stable cell coating.\n\nResearch efforts were hugely successful with regard to wearability, mobility and utility. AMBULUNG developed a small and lightweight innovatively shaped gas exchanger with a cellularisation-capable diffusion membrane. The miniaturised hardware including the disposable components weigh under three kg. A key feature is the reduced blood volume required outside the body that should reduce risk for patient. The prototypes developed for the entire system were successfully tested in a laboratory setting as well as in animals and patent applications have been filed.\n\nThe AMBULUNG team are continuing to work together after the end of the project to further optimise and validate this system in a clinical setting. Their bioartificial lung system would promote mobility and self-management rather than hospitalisation for COPD patients, thus giving them a good quality of life. COPD patients can look forward to rapid commercialisation thanks to extensive industrial partner experience with artificial lungs.\u003C\/sectionBody\u003E\u003C\/section\u003E","keywords":"Artificial lung, COPD, AMBULUNG, EC, diffusion membrane, bioreactor","contentCreationDate":"2015-01-21 16:30:17","contentUpdateDate":"2016-06-03 17:37:09","lastUpdateDate":"2025-09-17 22:38:23","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"104053","id":"304932","acronym":"AMBULUNG","teaser":"Chronic obstructive pulmonary disease (COPD) is the 4th leading cause of death worldwide. Long-term respiratory support increases the life expectancy and the quality of life of COPD patients and decreases the cost of care. Currently available artificial lungs, such as Novalung...","title":"Ambulatory Bio-Artificial Lung","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/71\/443\/1195","title":"bioreactors","displayCode":"\/engineering and technology\/environmental biotechnology\/bioremediation\/bioreactors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37\/163\/657","title":"stem cells","displayCode":"\/medical and health sciences\/medical biotechnology\/cells technologies\/stem cells","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/51\/355\/1059","title":"mathematical model","displayCode":"\/natural sciences\/mathematics\/applied mathematics\/mathematical model","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-FP","title":"Small or medium-scale focused research project","displayCode":"\/Small or medium-scale focused research project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"852","code":"FP7-HEALTH","frameworkProgramme":"FP7","pga":"FP7-HEALTH","title":"Specific Programme \u0022Cooperation\u0022: Health","shortTitle":"Health","parent":{"rcn":"846\/1401\/837","code":"FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"ppm","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"18365","code":"HEALTH.2012.1.4-2","frameworkProgramme":"FP7","title":"Medical technology for transplantation and bioartificial organs","parent":{"rcn":"10230\/10226\/11416\/852\/846\/1401\/837","code":"HEALTH-2007-1.4\/HEALTH-1\/HEALTH\/FP7-HEALTH\/FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"ppm","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"175848","title":"Final Report Summary - AMBULUNG (Ambulatory Bio-Artificial Lung)","teaser":"The idea to initiate the Ambulung project was based on the unmet medical needs to adequately treat patients, who suffer from severe COPD, a chronic pulmonary disease, which is the 4th leading cause of death worldwide. Following this idea, we...","contentUpdateDate":"2016-01-19 14:46:20","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"104053","id":"304932","title":"Ambulatory Bio-Artificial Lung","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/71\/443\/1195","title":"bioreactors","displayCode":"\/engineering and technology\/environmental biotechnology\/bioremediation\/bioreactors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37\/163\/657","title":"stem cells","displayCode":"\/medical and health sciences\/medical biotechnology\/cells technologies\/stem cells","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/51\/355\/1059","title":"mathematical model","displayCode":"\/natural sciences\/mathematics\/applied mathematics\/mathematical model","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-FP","title":"Small or medium-scale focused research project","displayCode":"\/Small or medium-scale focused research project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2016-06\/175848.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Thinkstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}