{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"169550","id":"169550-smart-retrofitting-of-older-buildings","title":"Smart retrofitting of older buildings","teaser":"A research project is well on the way to delivering an enveloping system which will improve the energy efficiency of older, multi-storey residential buildings.","body":"\u003Csection\u003E\u003CsectionBody\u003EArchitects and engineers work with the latest standards and materials in order to reduce heat loss in new buildings. However, making older stock more energy efficient is a greater challenge, often requiring the retrofitting of insulation materials both inside and out. In addition, many older buildings have preservation orders to protect them from significant alterations.\n\nThe EASEE (Envelope Approach to improve Sustainability and Energy efficiency in Existing multi-storey multi-owner residential buildings) project is tackling these issues by developing different types of advanced insulating components and materials for the three main envelope parts \u2013 the outer fa\u00e7ade, cavity walls and interiors. The project has also designed a new consulting software tool for the building sector called the Retrofitting Planner.\n\nFor the outer fa\u00e7ade, the project team has developed prefabricated insulating panels, which are made of textile reinforced mortar (TRM) with a core of polystyrene foam. The panels are hung from a building\u2019s exterior using special devices made of Ultra High Performance Fibre Reinforced Concrete (UHPRFC). The panels can be produced in different sizes, thicknesses and forms, allowing for tailored retrofitting to a variety of buildings. Plus, the installation method does away with the need for scaffolding.\n\nAs part of the assessment process, 40 panels were manufactured and installed at a residential building in Poland. The insulation value of the panels is expected to be 60 % greater than the base wall. Full-scale testing of this product is now underway on a three-floor building in Milan which contains 6 apartments. The design will use 186 panels with different colours and textures. The building envelope has been mapped using 3D laser scanning techniques to provide a high degree of accuracy and detail. The Retrofitting Planner was used to evaluate cost, performance and return on investment.\n\nFor the cavity walls, the project has developed a water-repelling process for both natural and synthetic expanded perlite. The insulating materials have been tested in the cavity walls of the Milan fa\u00e7ade and reveal an 89 % improvement in heat retention. In addition, the synthetic perlite was developed using mineral waste, recycled materials and industrial by-products. The main advantage of this product is that its formulation can be altered in order to meet different requirements.\n\nEASEE has delivered three kits for interior retrofitting, all of which have been prototyped and installed at the Milan site. A light-weight perlite insulating board comes complete with a dedicated adhesive mortar and a thin layer of finishing render. This innovation offers improved thermal performance compared to existing, similar products. A permeable insulating wall-paper has been produced by impregnating a textile product made of non-woven polyester fibres and aerogel. The lightweight wall-paper is thin and easy to roll \u2013 and can be handled by one or two people. Finally, a flat laminated board has been created using an aerogel and textile insulating layer which delivers improved thermal performance.\n\nProject coordinator, Andrea Ferrari, said: \u2018What we have aimed for in our work is to offer flexible solutions to improve the energy performance of older buildings \u2013 especially those constructed before the 1970s \u2013 which often cannot be altered with invasive construction work. Our innovations can be used together or separately depending on the building in question. What is more, the installation of EASEE products can be achieved with minimal disruption to residents \u2013 as our Milan test-bed is proving.\u2019\u003C\/sectionBody\u003E\u003C\/section\u003E","keywords":"EASEE, insulation, wall-paper, residential buildings, perlite, fa\u00e7ade, energy efficiency","contentCreationDate":"2015-09-01 16:47:17","contentUpdateDate":"2015-12-11 17:53:50","lastUpdateDate":"2017-02-13 14:21:32","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"env","title":"Climate Change and Environment","displayCode":"\/Climate Change and Environment","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"400003","id":"400003-retrofitting-buildings","title":"Old meets green: New technologies to retrofit buildings in Europe","teaser":"A great deal of EU-funded projects are focusing on the building renovation industry to accelerate the adoption of energy-efficient materials and technologies.","contentUpdateDate":"2015-12-04 12:17:33","relations":{"categories":[{"language":"en","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","code":"SME","title":"Small or Medium Size Enterprise (SME)","displayCode":"\/Small or Medium Size Enterprise (SME)","attributes":{"classification":"audience","type":"isTargetedTo"}},{"language":"en","code":"LOCREG","title":"Local and regional authority","displayCode":"\/Local and regional authority","attributes":{"classification":"audience","type":"isTargetedTo"}},{"language":"en","code":"ENTR","title":"Enterprise and industry organisation","displayCode":"\/Enterprise and industry organisation","attributes":{"classification":"audience","type":"isTargetedTo"}},{"language":"en","code":"RTD.D","title":"RTD - Industrial Technologies","description":"2016","displayCode":"\/RTD - Industrial Technologies","attributes":{"classification":"client","type":"isRequestedBy"}},{"language":"en","code":"resultsPack","title":"Results Pack","description":"Article: Collections of results, from finished or nearly completed projects, focusing on a specific theme that you can apply in your domain","displayCode":"\/Results Pack","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"104538","id":"314326","acronym":"NEWBEE","title":"Novel Business model generator for Energy Efficiency in construction and retrofitting","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169","title":"renewable energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/11936537\/91827000","title":"climatic change mitigation","displayCode":"\/engineering and technology\/environmental engineering\/ecosystem-based management\/climatic change mitigation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/91\/523\/1307","title":"business models","displayCode":"\/social sciences\/economics and business\/business and management\/business models","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/77\/479\/1267\/1749","title":"sustainable building","displayCode":"\/engineering and technology\/civil engineering\/architecture engineering\/sustainable architecture\/sustainable building","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-TP","title":"Collaborative Project targeted to a special group (such as SMEs)","displayCode":"\/Collaborative Project targeted to a special group (such as SMEs)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"105487","id":"314283","acronym":"HERB","title":"Holistic energy-efficient retrofitting of residential buildings","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169","title":"renewable energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/75\/471","title":"thermodynamic engineering","displayCode":"\/engineering and technology\/mechanical engineering\/thermodynamic engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"110304","id":"609222","acronym":"FASUDIR","title":"Friendly and Affordable Sustainable Urban Districts Retrofitting","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/307","title":"software","displayCode":"\/natural sciences\/computer and information sciences\/software","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/91\/523\/1307","title":"business models","displayCode":"\/social sciences\/economics and business\/business and management\/business models","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP","title":"Collaborative project (generic)","displayCode":"\/Collaborative project (generic)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"106000","id":"308816","acronym":"GREENHP","title":"Next generation heat pump for retrofitting buildings","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/75\/471","title":"thermodynamic engineering","displayCode":"\/engineering and technology\/mechanical engineering\/thermodynamic engineering","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169\/1685\/85521413","title":"solar thermal","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy\/solar energy\/solar thermal","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP","title":"Collaborative project (generic)","displayCode":"\/Collaborative project (generic)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"100470","id":"260058","acronym":"E2REBUILD","title":"Industrialised energy efficient retrofitting of resident buildings in cold climates","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/77\/479\/1267\/1749","title":"sustainable building","displayCode":"\/engineering and technology\/civil engineering\/architecture engineering\/sustainable architecture\/sustainable building","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP","title":"Collaborative project (generic)","displayCode":"\/Collaborative project (generic)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"102518","id":"285540","acronym":"EASEE","title":"Envelope Approach to improve Sustainability and Energy efficiency in Existing multi-storey multi-owner residential buildings","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/11936537\/91827000","title":"climatic change mitigation","displayCode":"\/engineering and technology\/environmental engineering\/ecosystem-based management\/climatic change mitigation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"102074","id":"285411","acronym":"MEEFS RETROFITTING","title":"Multifunctional Energy Efficient Fa\u00e7ade System for Building Retrofitting","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/11936537\/91827000","title":"climatic change mitigation","displayCode":"\/engineering and technology\/environmental engineering\/ecosystem-based management\/climatic change mitigation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/63\/387","title":"composites","displayCode":"\/engineering and technology\/materials engineering\/composites","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/369","title":"polymer sciences","displayCode":"\/natural sciences\/chemical sciences\/polymer sciences","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"105921","id":"600058","acronym":"URB-Grade","title":"URB-Grade: Decision Support Tool for Retrofitting a District, Towards the District as a Service","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/453\/58525161","title":"sensors","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/electronic engineering\/sensors","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP","title":"Collaborative project (generic)","displayCode":"\/Collaborative project (generic)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ppm","title":"PPM","description":"CNECT project management system","displayCode":"\/PPM","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"104743","id":"314461","acronym":"INSPIRE","title":"Development of Systemic Packages for Deep Energy Renovation of Residential and Tertiary Buildings including Envelope and Systems","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169","title":"renewable energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"rcn":"104534","id":"314229","acronym":"RETROKIT","title":"RetroKit - Toolboxes for systemic retrofitting","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/45\/30018\/30032\/835","title":"climatic zones","displayCode":"\/natural sciences\/earth and related environmental sciences\/atmospheric sciences\/climatology\/climatic zones","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/29\/91\/523\/1307","title":"business models","displayCode":"\/social sciences\/economics and business\/business and management\/business models","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/article\/images\/2016-04\/400003.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}},{"language":"en","availableLanguages":"en","defaultLanguage":"en","title":"Energy-efficient Buildings (EeB) - Research \u0026 Innovation - Key Enabling Technologies - European Commission","id":"faa68eeb20b40c8e0087d4384a9f81fd","description":"More about research and innovation in the field of Energy-efficient Buildings:","physUrl":"http:\/\/ec.europa.eu\/research\/industrial_technologies\/energy-efficient-buildings_en.html","status":"legacy","contenttype":"webLink","attributes":{"represents":"article","source":"editorial","type":"relatedWebsite"}}]},"contenttype":"article","attributes":{"source":"editorial","type":"isContainedIn"}},{"availableLanguages":"en","rcn":"102518","id":"285540","acronym":"EASEE","teaser":"EASEE aims at developing a tool-kit for energy efficient envelope retrofitting of existing multi-storey and multi-owner buildings which combines novel design and assessment strategies, modular prefabricated elements, advanced insulating materials and new scaffolding-free inst...","title":"Envelope Approach to improve Sustainability and Energy efficiency in Existing multi-storey multi-owner residential buildings","archivedDate":"2024-05-28 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/11936537\/91827000","title":"climatic change mitigation","displayCode":"\/engineering and technology\/environmental engineering\/ecosystem-based management\/climatic change mitigation","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"CP-IP","title":"Large-scale integrating project","displayCode":"\/Large-scale integrating project","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"854","code":"FP7-NMP","frameworkProgramme":"FP7","pga":"FP7-NMP","title":"Specific Programme \u0022Cooperation\u0022: Nanosciences, Nanotechnologies, Materials and new Production Technologies","shortTitle":"Nanosciences, nanotechnologies, materials and new production technologies","parent":{"rcn":"846\/1401\/837","code":"FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"17069","code":"EeB.NMP.2011-3","frameworkProgramme":"FP7","title":"Energy saving technologies for buildings envelope retrofitting","parent":{"rcn":"17048\/17049\/13178\/19513\/854\/846\/1401\/837","code":"NMP-5.2.1\/NMP-5.2\/NMP-5\/NMP\/FP7-NMP\/FP7-COOPERATION\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2015-12\/159206.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 EASEE","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}