{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"191000","id":"191000-an-improved-treatment-for-cardiac-arrhythmia","title":"An improved treatment for cardiac arrhythmia","teaser":"Arrhythmias are a major cause of death and disability worldwide, and their prevalence is expected to rise with the ageing of the population. Effective treatment necessitates precise localisation of the cardiac lesion.","body":"\u003Csection\u003E\u003CsectionBody\u003ECardiac arrhythmias are treated or even cured using ablation with a radio-frequency (RF) catheter. However, this approach requires direct contact with the endocardium, thereby limiting the depth of the tissue injury that can be treated. In addition, there is no imaging modality for real-time monitoring of the treatment and for accurate assessment of the lesion.\n\nThe objective of the EU-funded HIFUSWI-INTRACARDIAC (High-intensity focused ultrasound intracardiac ablation with real-time monitoring using shear-wave imaging) project was to construct an ultrasound-based intracardiac system that could perform ablation in combination with real-time imaging. Towards this goal, the team combined high-intensity focused ultrasound and shear wave imaging (SWI). This allowed them to monitor the size and temperature of the ablation in real time in ex\u00a0vivo heart samples. The idea was to be able to pinpoint the region to ablate with accuracy alongside a temperature map and close monitoring of the amount of energy to be sent to the tissue.\n\nResearchers generated shear waves by the intracardiac transducer at depths of up to 15\u00a0mm. They validated and optimised the system in an animal model by monitoring the growth and temperature of cardiac lesions. They also measured the variation of cardiac stiffness over the cardiac cycle and after RF ablation. Importantly, the consortium demonstrated the feasibility of performing real-time RF ablation monitoring in patients using SWI.\n\nOverall, the HIFUSWI-INTRACARDIAC system demonstrated the capacity to ablate the cardiac tissue at any location in the thickness of the myocardium while simultaneously assessing the size and temperature of the lesion. This is expected to accelerate procedures, reduce procedure-associated risks and provide a new approach to assess the success of the ablation.\u003C\/sectionBody\u003E\u003C\/section\u003E","keywords":"Cardiac arrhythmia, cardiac lesion, ablation, HIFUSWI-INTRACARDIAC, shear wave imaging","contentCreationDate":"2017-02-07 10:47:55","contentUpdateDate":"2017-02-07 10:47:45","lastUpdateDate":"2017-02-07 10:48:07","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"103923","id":"301340","acronym":"HIFUSWI-INTRACARDIAC","teaser":"Arrhythmias are a major cause of death and disability worldwide and their prevalence is expected to rise with the aging of the population. Recent technological advances have led to the development of new treatments based on radio-frequency (RF) catheter ablation to treat and ...","title":"High-intensity focused ultrasound intracardiac ablation with real-time monitoring using shear-wave imaging","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/30020\/455\/1225\/1723","title":"radio frequency","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/information engineering\/telecommunications\/radio technology\/radio frequency","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/221\/713\/38221291","title":"cardiac arrhythmia","displayCode":"\/medical and health sciences\/clinical medicine\/cardiology\/cardiovascular diseases\/cardiac arrhythmia","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/273\/813","title":"ultrasound","displayCode":"\/natural sciences\/physical sciences\/acoustics\/ultrasound","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MC-IIF","title":"International Incoming Fellowships (IIF)","displayCode":"\/International Incoming Fellowships (IIF)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"848","code":"FP7-PEOPLE","frameworkProgramme":"FP7","pga":"FP7-PEOPLE","title":"Specific programme \u0022People\u0022 implementing the Seventh Framework Programme of the European Community for research, technological development and demonstration activities (2007 to 2013)","shortTitle":"Specific Programme \u0022People\u0022","parent":{"rcn":"1401\/837","code":"EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"17114","code":"FP7-PEOPLE-2011-IIF","frameworkProgramme":"FP7","title":"Marie Curie Action: \u0022International Incoming Fellowships\u0022","parent":{"rcn":"10068\/11419\/848\/1401\/837","code":"PEOPLE-4\/PEOPLE\/FP7-PEOPLE\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"187494","title":"Final Report Summary - HIFUSWI-INTRACARDIAC (High-intensity focused ultrasound intracardiac ablation with real-time monitoring using shear-wave imaging)","teaser":"Arrhythmias are a major cause of death and disability worldwide and their prevalence is expected to rise with the aging of the population. Recent technological advances have led to the development of new treatments based on radio-frequency (RF) catheter ablation to treat and...","contentUpdateDate":"2016-08-11 12:26:35","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"103923","id":"301340","title":"High-intensity focused ultrasound intracardiac ablation with real-time monitoring using shear-wave imaging","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/73\/30020\/455\/1225\/1723","title":"radio frequency","displayCode":"\/engineering and technology\/electrical engineering, electronic engineering, information engineering\/information engineering\/telecommunications\/radio technology\/radio frequency","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/221\/713\/38221291","title":"cardiac arrhythmia","displayCode":"\/medical and health sciences\/clinical medicine\/cardiology\/cardiovascular diseases\/cardiac arrhythmia","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/273\/813","title":"ultrasound","displayCode":"\/natural sciences\/physical sciences\/acoustics\/ultrasound","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MC-IIF","title":"International Incoming Fellowships (IIF)","displayCode":"\/International Incoming Fellowships (IIF)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2017-02\/191000.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Designua, Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"France","rcn":"258902568","nutsCode":"FR","euCode":"FR","isoCode":"FR","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}