{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"198615","id":"198615-janus-micromotors-now-in-labonachip-devices","title":"Janus micromotors now in lab-on-a-chip devices","teaser":"EU funding has enabled researchers to develop micromotors. These were integrated into lab-on-a-chip (LOC) devices for myriad applications, including health, food and environmental safety.","body":"\u003Csection\u003E\u003CsectionBody\u003EThe team made significant inroads during the 36-month duration of the project LOCNANOMOT (New lab-on-a-chip microsystems based on active transport by synthetic micro\/nanomotors). Janus particles, namesake of the two-faced Roman god Janus, were chosen as they can incorporate different or incompatible properties in a single particle. Their objective was the development and integration of functionalised micromotors into microfluidic LOC devices to simultaneously perform multiple analyte detections from a sample.\n\nResearchers characterised and developed Janus micromotors and evaluated the impact of micromotors and catalytic nanowires on transport and fluid mixing. They also developed a novel protocol for sensing silver using the motion of metallic nanowires. \n\nNoteworthy is the use of graphene for making tubular microengines, for the first time. This development enabled researchers to use different kinds of receptors on graphene in next-generation LOC systems. The team also incorporated red blood cell particles on the surface of ultrasound-propelled gold nanowires in biomimetic motors.\n\nAn impressive achievement, researchers integrated quantum dot nanocrystals on the surface of template-prepared microengines for the simultaneous detection of multiple analytes. Such microsensors can be used to detect contaminants such as mercury and bacteria in samples.\n\nResearchers successfully came up with a Janus micromotor-based strategy for developing novel point-of-care devices that allow on-chip monitoring of toxic compounds in complex samples. They fabricated and developed carbon nanomaterial-based micromotors and integrated them into a LOC system. This system was then used for rare cell and bacteria isolation as well as food and biological samples analysis.\n\nStudy outcomes were impressive and results were published in numerous leading scientific journals. Applications abound in the healthcare, food and environmental sectors, with benefits for all. To name a few, these micromotor-based LOC systems can be used for pathogen detection, clinical diagnosis, forensic science, environmental remediation, DNA analysis and food safety.\u003C\/sectionBody\u003E\u003C\/section\u003E","keywords":"Janus micromotors, lab-on-a-chip, LOCNANOMOT, graphene, quantum dot, bacteria isolation","contentCreationDate":"2017-05-29 15:12:02","contentUpdateDate":"2017-05-29 15:11:55","lastUpdateDate":"2017-05-29 15:12:14","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"funda","title":"Fundamental Research","displayCode":"\/Fundamental Research","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"108161","id":"326476","acronym":"LOCNANOMOT","teaser":"\u0022The IOF project LOCNANOMOT aims to design new miniaturized Lab-on-a-Chip systems for multiplexed detections using functionalized artificial micro\/nanomotors modified with different receptors. To achieve this goal, a primary challenge of the outgoing phase (University of Cali...","title":"New lab-on-a-chip microsystems based on active \ntransport by synthetic micro\/nanomotors","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379\/16253769","title":"lab on a chip","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology\/lab on a chip","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MC-IOF","title":"International Outgoing Fellowships (IOF)","displayCode":"\/International Outgoing Fellowships (IOF)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"848","code":"FP7-PEOPLE","frameworkProgramme":"FP7","pga":"FP7-PEOPLE","title":"Specific programme \u0022People\u0022 implementing the Seventh Framework Programme of the European Community for research, technological development and demonstration activities (2007 to 2013)","shortTitle":"Specific Programme \u0022People\u0022","parent":{"rcn":"1401\/837","code":"EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"17624","code":"FP7-PEOPLE-2012-IOF","frameworkProgramme":"FP7","title":"Marie Curie Action: \u0022International Outgoing Fellowships for Career Development\u0022","parent":{"rcn":"10068\/11419\/848\/1401\/837","code":"PEOPLE-4\/PEOPLE\/FP7-PEOPLE\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"availableLanguages":"en","rcn":"191981","title":"Final Report Summary - LOCNANOMOT (New lab-on-a-chip microsystems based on active transport by synthetic micro\/nanomotors)","teaser":"The LOCNANOMOT project aims to develop new miniaturized lab-on-a-chip (LOC) systems for multiplexed detections using functionalized artificial micro\/nanomotors modified with different receptors. To achieve the stated goal, a primary challenge of the outgoing phase was the...","contentUpdateDate":"2016-11-16 16:59:19","archivedDate":"2024-06-23 00:00:00","relations":{"categories":[{"language":"en","code":"pubsum","title":"Report Summary","description":"Result: Publishable summary (FP7 SESAM) and Summary for publication (H2020 SyGMa)","displayCode":"\/Report Summary","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"sesam","title":"SESAM","description":"RTD FP7 reporting system (including FP6 Marie Curie)","displayCode":"\/SESAM","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"rcn":"108161","id":"326476","title":"New lab-on-a-chip microsystems based on active \ntransport by synthetic micro\/nanomotors","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379\/16253769","title":"lab on a chip","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology\/lab on a chip","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MC-IOF","title":"International Outgoing Fellowships (IOF)","displayCode":"\/International Outgoing Fellowships (IOF)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"project","attributes":{"source":"sesam","type":"relatedProject"}}]},"contenttype":"result","attributes":{"source":"editorial","type":"relatedResult"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2017-05\/198615.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 chombosan, Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Spain","rcn":"242387496","nutsCode":"ES","euCode":"ES","isoCode":"ES","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}