{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"224910","id":"224910-enhanced-imaging-of-the-heart","title":"Enhanced imaging of the heart","teaser":"European researchers with the JUNO project generated a new tool for assessment of cardiac images. Clinical implementation is expected to improve structural and functional evaluation of the heart both in the adult and in the foetus.","body":"\u003Csection\u003E\u003CsectionBody\u003ECardiovascular magnetic resonance (CMR) is a non-invasive imaging procedure aimed at the assessment of the structure and function of the cardiovascular system. The effectiveness of a CMR scan depends on the ability of the operator to correctly tune the acquisition parameters to the subject being scanned and on the potential occurrence of imaging artefacts such as cardiac and respiratory motion. Quality control on the acquired images is usually performed visually by the same operator. \n\nTo overcome this time-consuming and operator-dependent process, scientists of the EU-funded JUNO project developed an automated image processing approach to improve the quality control of CMR images. \u201cOur ultimate goal was to apply our technique to automatically detect almost in real time incomplete or corrupted scans, allowing the triggering of a new acquisition,\u2033 explains project coordinator Dr Daniel Rueckert.\n\nAdvancing CMR image processing\n\nThe JUNO automated technique employs machine learning to extract information from the acquired CMR images. The approach facilitates detection and correction of motion-corrupted images in CMR images by identifying whether the patient could not hold his\/her breath as required for proper image acquisition. In addition, it helped validate that the obtained image included the whole heart and also that the cardiac structures were visible and distinguishable.\n\nImplementation of the technique on thousands of scans obtained from the UK Biobank demonstrated high accuracy in the detection of problematic scans. With respect to sub-optimal heart coverage detection, the JUNO approach showed 88 % sensitivity and 99 % specificity while slightly lower percentages were obtained for motion-corrupted scan detection. Importantly, the motion correction technique outperformed other existing methods.\n\nClinical implementation of the JUNO technique\n\nThe JUNO approach is potentially directly applicable in the clinic as a tool for automated quality control of CMR images in the adult. In fact, the relatively low computational time (around 15 seconds are needed to evaluate a typical scan) makes it deployable in the busy clinical routine to inform the operators of potentially corrupted scans and to allow the re-acquisition of the images while the patient is still in the scanner.\n\nJUNO researchers believe the technique will also be able to facilitate future clinical studies. With the launch of several initiatives for the acquisition of large-scale open-access databases consisting of thousands of CMR images (such as the UK Biobank), a fully automated quality control pipeline like JUNO is needed to detect corrupted scans and exclude them from the following analyses. \n\nFurthermore, the JUNO technique has the potential to be also applied for the motion correction of foetal CMR scans, which are gaining more and more diffusion thanks to recent technological developments. This means that the JUNO approach could provide a more reliable reconstruction of the foetal heart.\n\nAlthough the JUNO approach was not directly tested in the clinic, Dr Rueckert believes \u201cthe technique should eventually be released online, freely accessible by research groups and clinics all over the world, addressing the need for reliable fully-automated quality assessment of CMR scans.\u2033\u003C\/sectionBody\u003E\u003C\/section\u003E","keywords":"JUNO, cardiovascular magnetic resonance (CMR), foetal heart, automated quality control","contentCreationDate":"2018-04-18 12:25:16","contentUpdateDate":"2018-04-18 12:24:49","lastUpdateDate":"2022-08-05 21:47:13","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"195037","id":"655033","acronym":"JUNO","teaser":"Recent advancements in cardiovascular magnetic resonance (CMR) have finally made possible static and dynamic in-vivo imaging of the fetal heart. This new capability has the potential to provide a fundamental new tool for structural and functional assessment of the fetal...","title":"Joint Volumetric Reconstruction and Automated Analysis of the Fetal Heart from Cardiovascular Magnetic Resonance Images","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/297\/933\/36035695","title":"semisupervised learning","displayCode":"\/natural sciences\/computer and information sciences\/artificial intelligence\/machine learning\/semisupervised learning","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/47\/303","title":"databases","displayCode":"\/natural sciences\/computer and information sciences\/databases","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/221\/711","title":"paediatric cardiology","displayCode":"\/medical and health sciences\/clinical medicine\/cardiology\/paediatric cardiology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/51\/359\/1067\/81178764","title":"functional analysis","displayCode":"\/natural sciences\/mathematics\/pure mathematics\/mathematical analysis\/functional analysis","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/203","title":"embryology","displayCode":"\/medical and health sciences\/clinical medicine\/embryology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MSCA-IF-EF-ST","title":"Standard EF","description":"Standard EF","displayCode":"\/Standard EF","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664109","code":"H2020-EU.1.3.","frameworkProgramme":"H2020","pga":"H2020-EU.1.3.","title":"EXCELLENT SCIENCE - Marie Sk\u0142odowska-Curie Actions","shortTitle":"Marie-Sklodowska-Curie Actions","parent":{"rcn":"664091\/664087\/664086","code":"H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664113","code":"H2020-EU.1.3.2.","frameworkProgramme":"H2020","pga":"H2020-EU.1.3.2.","title":"Nurturing excellence by means of cross-border and cross-sector mobility","shortTitle":"MSCA Mobility","parent":{"rcn":"664109\/664091\/664087\/664086","code":"H2020-EU.1.3.\/H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"664546","code":"MSCA-IF-2014-EF","frameworkProgramme":"H2020","title":"Marie Sk\u0142odowska-Curie Individual Fellowships (IF-EF)","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2018-04\/224910.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Semnic, Shutterstock","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}