{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"227602","id":"227602-novel-dry-electrode-eeg-system-for-brain-research-in-a-cap","title":"Novel dry electrode EEG system for brain research in a cap","teaser":"Multichannel electroencephalography (EEG) is a well-established method for investigating the function of the human brain. EU researchers developed a cap that overcomes drawbacks in signal acquisition on the head surface by eliminating the need for paste\/gel application.","body":"\u003Csection\u003E\u003CsectionBody\u003EDespite continuous advancements in signal amplification and data processing, difficult and error-prone signal acquisition on the head surface is still a major issue limiting EEG use in basic and clinical research. The EU-funded http:\/\/www.andreaproject.eu\/ (ANDREA) project integrated a novel concept dry electrode technology with an adjustable cap network. As project coordinator Prof. Silvia Comani points out, \u201cThe system meets the requirements for high signal quality and reliability, mobility, high patient\/subject comfort and long-term use.\u201d\n\nThe cap provides an automated sensor positioning mechanism, flexible compliant electrode shape and a software toolbox for the automatic classification and removal of the main artefacts that might affect the EEG recordings. \u201cThe novel technologies were validated in clinical (neurological patients) and non-clinical (athletes) populations to produce a system optimised for a broad range of EEG applications,\u201d says Prof. Comani.\n\nDry vs wet\n\nThis innovative headset has a dry electrode system. The electrode composition is such that it avoids all the drawbacks of applying conductive paste to reduce the impedance between the head scalp and the sensor. \n\nA \u2018wet\u2019 system also has other disadvantages. For instance, the wearer can develop allergies to the gel and the paste may leak forming cross-bridges between electrodes. Drying of the paste also introduces error due to decreased signal quality.\n\nOne big advantage factor is related to the speed with which the dry cap can be fitted. This is very relevant where fast action is of critical importance. Challenging conditions like epilepsy can be tackled quickly enough to reconstruct the foci for accurate surgery.\n\nImpressive array of new features\n\nThe EEG cap system is plug-and-play and is designed to combine user comfort with state-of-the-art performance for brain research. The multi-pin electrodes are light weight and mechanically flexible with a nanostructured conductive coating for stable and reliable readings. Moreover, the different multi-pin shapes can fit different scalp areas to increase signal quality and offer maximum comfort for the wearer.\n\nA modular concept allows the application of eight to sixty-four electrodes. Active preamplification electronics improves the signal quality at increased electrode-skin impedance levels. Electrical impedance of biological materials reflects the clinical status of the tissue under study.\n\nTogether with algorithms for automatic artefact rejection and the optimised software toolbox, the system detects and rejects artefactual components in EEG datasets recorded with different types of electrodes and cap layouts.\n\n All-important knowledge transfer at every level\n\nANDREA successfully set up some 44 secondments of staff members belonging to a different sector for a total of 99 person-months. \u201cThis programme also contributed to the sharing of different cultures and knowledge among partners,\u201d emphasises Prof. Comani.\n\nAs a result, the research capacity, international visibility and competitiveness of each partner was significantly enhanced. This in itself has led and will continue to lead to several well-received interdisciplinary scientific publications.\n\nFuture research path\n\nSome ANDREA partners have already submitted new project proposals for the development of dry electrodes that will monitor brain function in newborns to prevent neurological, cognitive and motor impairment in later life. This presents new challenges related to skin sensitivity of such young subjects. \n\nAnother direction lies with social interaction and coordination studies but this must incorporate full-body motion to be meaningful. The dry EEG system must therefore be robust with stable skin-electrode contact for reliable brain signal monitoring.\n\nA grand total of 82 dissemination activities were directed at both the specialist and general public. National and international scientific conferences, international fairs, events organised by scientific societies and open days at universities were among the activities.\n\nProf. Comani sums up the resounding success of the ANDREA project. \u201cBased on the sound technological advances in the dry electrode EEG system coupled with dissemination and collaboration, we expect that the ANDREA network will become a permanent EU research network promoting health technology in Europe.\u201d\u003C\/sectionBody\u003E\u003C\/section\u003E","keywords":"ANDREA, dry electrode, EEG, cap, brain","contentCreationDate":"2018-05-11 16:02:57","contentUpdateDate":"2018-05-11 16:02:49","lastUpdateDate":"2018-05-11 16:03:11","archivedDate":"2024-06-10 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ict","title":"Digital Economy","displayCode":"\/Digital Economy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"funda","title":"Fundamental Research","displayCode":"\/Fundamental Research","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"109927","id":"610950","acronym":"ANDREA","teaser":"\u0022Multichannel electroencephalography (EEG) is a well-established method for investigating the function of the human brain, but, despite continuous advancements in signal amplification and data processing, difficult and error-prone signal acquisition on the head surface is sti...","title":"Active Nanocoated DRy-electrode for Eeg Applications","archivedDate":"2024-06-18 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/37","title":"medical biotechnology","displayCode":"\/medical and health sciences\/medical biotechnology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/241","title":"clinical neurology","displayCode":"\/medical and health sciences\/clinical medicine\/clinical neurology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MC-IAPP","title":"Industry-Academia Partnerships and Pathways (IAPP)","displayCode":"\/Industry-Academia Partnerships and Pathways (IAPP)","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"848","code":"FP7-PEOPLE","frameworkProgramme":"FP7","pga":"FP7-PEOPLE","title":"Specific programme \u0022People\u0022 implementing the Seventh Framework Programme of the European Community for research, technological development and demonstration activities (2007 to 2013)","shortTitle":"Specific Programme \u0022People\u0022","parent":{"rcn":"1401\/837","code":"EC\/FP7"},"archivedDate":"2024-06-12 00:00:00","relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"19058","code":"FP7-PEOPLE-2013-IAPP","frameworkProgramme":"FP7","title":"Marie Curie Action: \u0022Industry-Academia Partnerships and Pathways\u0022","parent":{"rcn":"10067\/11419\/848\/1401\/837","code":"PEOPLE-3\/PEOPLE\/FP7-PEOPLE\/EC\/FP7"},"archivedDate":"2024-06-14 00:00:00","relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2018-05\/227602.jpg","mimetype":"image\/jpeg","size":"0","copyright":"\u00a9 Silvia Comani","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}