{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"32647","id":"32647-researchers-develop-method-for-detailed-imaging-of-fragile-bone-structures","title":"Researchers develop method for detailed imaging of fragile bone structures","teaser":"Scientists working in Germany and Switzerland have developed a novel nano-tomography method, which uses X-rays to allow doctors to produce three-dimensional (3D) detailed imaging of fragile bone structures. This method could lead to the development of better therapeutic approa...","body":"\u003Csection\u003E\u003CsectionBody\u003EScientists working in Germany and Switzerland have developed a novel nano-tomography method, which uses X-rays to allow doctors to produce three-dimensional (3D) detailed imaging of fragile bone structures. This method could lead to the development of better therapeutic approaches to tackle the brittle bone disease osteoporosis, one of the most common disorders among older people. The new method was recently presented in the journal Nature.\n\nThe researchers from the Technische Universitaet Muenchen (TUM) in Germany, the Paul Scherrer Institute in Switzerland and the Swiss Federal Institute of Technology (ETH-Zurich) said osteoporosis is currently diagnosed almost exclusively by establishing an overall reduction in bone density. This new method will give much greater information about the associated local structure and bone density changes. Until now doctors have been hampered by their lack of ability to look in detail at changes to bone density. \n\nTUM\u0027s Professor Franz Pfeiffer said this is all about to change. \u0027With our newly developed nano-CT [computed tomorgraphy] method it is now possible to visualise the bone structure and density changes at high resolutions and in 3D,\u0027 explained Professor Pfeiffer, who led the research. This will \u0027enable us to do research on structural changes related to osteoporosis on a nanoscale and thus develop better therapeutic approaches\u0027.\n\nProfessor Pfeiffer\u0027s team used X-ray CT to develop its method. CT scanners are used every day in hospitals and medical practices for the diagnostic screening of the human body - the body is X-rayed while a detector records from different angles how much radiation is being absorbed. \n\n\u0027In principle it is nothing more than taking multiple X-ray pictures from various directions,\u0027 the authors said. \u0027A number of such pictures are then used to generate digital 3D images of the body\u0027s interior using image processing.\u0027\n\nThe new method measures both the overall beam intensity absorbed by the object under examination at each angle and the parts of the X-ray beam that are deflected in different directions or \u0027diffracted\u0027. A diffraction pattern is generated for every point in the sample and this supplies additional information about the exact nanostructure, as X-ray radiation is particularly sensitive to the tiniest of structural changes, according to the researchers. \n\n\u0027Because we have to take and process so many individual pictures with extreme precision, it was particularly important during the implementation of the method to use high-brilliance X-ray radiation and fast, low-noise pixel detectors,\u0027 said Oliver Bunk, who was responsible for the experimental setup at the PSI synchrotron facilities in Switzerland.\n\nThe diffraction patterns were then processed using an algorithm developed by the team, TUM researcher Martin Dierolf stated. \u0027We developed an image reconstruction algorithm that generates a high-resolution, 3D image of the sample using over 100,000 diffraction patterns,\u0027 he said. \u0027This algorithm takes into account not only classical X-ray absorption, but also the significantly more sensitive phase shift of the X-rays.\u0027 \n\nRoger Wepf, Director of the Electron Microscopy Centre at ETH Zurich (EMEZ), acknowledged that while \u0027the new nano-CT procedure does not achieve the spatial resolution currently available in electron microscopy\u0027, \u0027it can - because of the high penetration of X-rays - generate 3D tomography images of bone samples\u0027. \n\nHe said, \u0027The new nano-CT procedure also stands out with its high precision bone density measurement capacity, which is particularly important in bone research.\u0027 The researchers noted that the method will open the door to more precise studies on the early phase of osteoporosis and to the evaluation of the therapeutic outcomes of various treatments in clinical studies.\u003C\/sectionBody\u003E\u003C\/section\u003E","basedOn":"Nature","contentCreationDate":"2010-10-13 00:00:00","contentUpdateDate":"2010-10-13 00:00:02","lastUpdateDate":"2023-03-08 05:20:50","archivedDate":"2023-03-07 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"regions":[{"name":"Switzerland","rcn":"205949480","nutsCode":"CH","euCode":"CH","isoCode":"CH","attributes":{"source":"editorial","type":"relatedRegion"}},{"name":"Germany","rcn":"221940264","nutsCode":"DE","euCode":"DE","isoCode":"DE","attributes":{"source":"editorial","type":"relatedRegion"}}],"associations":[{"language":"en","availableLanguages":"en,any","uri":"\/docs\/news\/images\/2010-10\/20101013-3.jpg","mimetype":"image\/jpeg","size":"0","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}