{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"413191","id":"413191-an-innovative-method-to-detect-cancerous-cells-in-blood","title":"An innovative method to detect cancerous cells in blood","teaser":"Current methods for identifying specific types of cells in blood require laborious biomarker labelling techniques. An EU-funded project has developed an innovative label-free system based on electrical signals for detecting rare tumour cells.","body":"\r\n    \u003Csection\u003E\r\n      \u003CsectionBody\u003ERare cells that originate in tumours can travel in the bloodstream and sometimes spread to other organs in the body. But because circulating tumour cells (CTCs) are so rare, detecting them is like finding a needle in a haystack. \r\n\r\n\u201cOnly a few cells in 1 ml of blood are CTCs while there are millions or even billions of other cells including white blood cells and red blood cells,\u201d says pureCTC project coordinator Wim de Malsche, a professor in the department of chemical engineering at the https:\/\/www.vub.be\/en (Free University of Brussels (VUB)), Belgium. \u201cIt is not that easy to detect all kinds of cancers.\u201d\r\n\r\nExisting systems for detecting specific types of cells all involve prior biomarker labelling. But with wide variation in CTCs this would be cumbersome and complex to use.\r\n\r\nIn order to bypass labelling and produce a generic method that can detect CTCs from many different types of cancers, the project developed a microfluidic platform for high throughput screening to identify and isolate CTCs at the single-cell level using electrochemical methods.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n    \u003Csection\u003E\r\n      \u003CsectionTitle\u003ELabel-free system\u003C\/sectionTitle\u003E\r\n      \u003CsectionBody\u003EDifferent cancer cells have different electrical properties that can be detected by electrical signals. A technique known as electrochemical impedance spectroscopy was used to identify the CTCs. \u201cAs those cells flow by, you apply an oscillating electrical signal and you get an output from that. Based on that signature you can discriminate those cancer cells from white blood cells and red blood cells,\u201d de Malsche explains. \r\n\r\n\u201cWe have developed a platform that consists of two coupled devices,\u201d says Sertan Sukas, currently a postdoctoral researcher at the department of biomedical engineering at https:\/\/www.tue.nl\/en\/ (Eindhoven University of Technology), the Netherlands. He received a Marie Sk\u0142odowska-Curie programme grant for 2 years to set up a special interdisciplinary laboratory at VUB for the project. \r\n\r\n\u201cThe first component is to stream the blood sample in and do pre-enrichment, using acoustofocusing or acoustophoresis; the second part is the detector which consists of integrated electrodes for impedance sensing,\u201d Sukas says. \r\n\r\nAcoustophoresis uses sound waves to move particles. The single cells can then be streamed through the detector\u2019s electrodes to identify the electrical properties on a cell-by-cell basis.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n    \u003Csection\u003E\r\n      \u003CsectionTitle\u003EEarly phase\u003C\/sectionTitle\u003E\r\n      \u003CsectionBody\u003EExperiments were based on blood from healthy people mixed with cancer cells. \u201cAt laboratory scale we have proof of concept,\u201d Sukas says.\r\n\r\n\u201cWe are still at an early phase and have only worked with cancer cell lines for now. But later on, the electrical properties can be matched to the properties of the cells,\u201d Sukas explains. \u201cWe have not yet been able to work with patient samples from hospitals, so we need to go to the next step to show it clinically.\u201d  \r\n\r\n\u201cWe will try to identify a few types of cancer and create a library. But we don\u2019t have that data yet \u2013 to do that first you need an optimised sensor and we are still working on that.\u201d  \r\n\r\nAs Sukas says: \u201cIn the end, we developed a sensitive electrical detection system which shows the potential of discriminating CTC tumour cells from the rest of the blood cells and also has the potential to be used as a haematology analyser, typically to inform about the content of the white blood cells.\u201d \r\n\r\n\u201cUsing a label-free system allows you to do further analysis,\u201d Sukas adds, noting it is more sensitive than a typical biomarker labelling system. \r\n\r\nA patent application is pending on the device.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n  ","keywords":"pureCTC, blood cells, cancer, cancer cells, tumour, biomarker, acoustophoresis, microfluidic, impedance sensing","contentCreationDate":"2020-01-03 15:21:41","contentUpdateDate":"2020-01-03 15:20:46","lastUpdateDate":"2022-08-15 15:18:01","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"it","rcn":"3765622","id":"edit-georgma","contenttype":"person","attributes":{"source":"editorial","type":"isWrittenBy"}},{"availableLanguages":"en","rcn":"209382","id":"752516","acronym":"pureCTC","teaser":"The overall objective of pureCTC is to realize a comprehensive lab-on-a-chip platform that redefines the state-of-the-art technology to address all the requirements for fast, efficient and reliable CTC isolation\/purification from whole blood.CTCs are rare cells that originate...","title":"A LAB-ON-A-CHIP DEVICE FOR PURE CIRCULATING TUMOR CELL ISOLATION FROM WHOLE BLOOD FOR CANCER THERAPY","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/59\/379\/16253769","title":"lab on a chip","displayCode":"\/engineering and technology\/other engineering and technologies\/microtechnology\/lab on a chip","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"MSCA-IF-EF-ST","title":"Standard EF","description":"Standard EF","displayCode":"\/Standard EF","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664109","code":"H2020-EU.1.3.","frameworkProgramme":"H2020","pga":"H2020-EU.1.3.","title":"EXCELLENT SCIENCE - Marie Sk\u0142odowska-Curie Actions","shortTitle":"Marie-Sklodowska-Curie Actions","parent":{"rcn":"664091\/664087\/664086","code":"H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664113","code":"H2020-EU.1.3.2.","frameworkProgramme":"H2020","pga":"H2020-EU.1.3.2.","title":"Nurturing excellence by means of cross-border and cross-sector mobility","shortTitle":"MSCA Mobility","parent":{"rcn":"664109\/664091\/664087\/664086","code":"H2020-EU.1.3.\/H2020-EU.1.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"700930","code":"MSCA-IF-2016","frameworkProgramme":"H2020","title":"Individual Fellowships","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/results\/images\/2019-12\/413191.jpg","mimetype":"image\/jpeg","size":"52572","copyright":"\u00a9 Sertan Sukas","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Belgium","rcn":"188385832","nutsCode":"BE","euCode":"BE","isoCode":"BE","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}