{"contenttype":"article","language":"en","availableLanguages":"en","rcn":"428882","id":"428882-amplitude-improving-bladder-cancer-diagnosis-and-therapy-monitoring","title":"AMPLITUDE - Improving Bladder Cancer Diagnosis and Therapy Monitoring","teaser":"Bladder cancer is among the most prevalent cancers in the world and is accompanied by similarly high morbidity and mortality. The Amplitude project aims to produce an imaging system capable of revolutionising current diagnostics of bladder cancer, with potential to improve diagnostics across a whole range of different forms of cancer, through deep tissue imaging made accessible to clinics.","description":"0","body":"\r\n    \u003Csection\u003E\r\n      \u003CsectionBody\u003EThe primary concern with bladder cancer is how invasive the tumour is when diagnosed. The more invasive, the higher the stage. If the tumour has not yet invaded as far as the muscle wall of the bladder when diagnosed, the tumour can be surgically excised through transurethral resection (TURBT), and 5-year survival is around 80%. If the tumour has invaded through the muscle wall when diagnosed, then treatment should instead be focused on complete bladder removal (cystectomy) and chemotherapy, or even a combination of radiotherapy, chemotherapy and surgery. 5-year survival if diagnosed at this later stage drops to around 40% when treated with radical cystectomy. About 20-25% of bladder cancers have invaded beyond the muscle wall by the time they are diagnosed.\r\n\r\nBladder cancer has higher recurrence rates than any other cancer type, and so for bladder cancer, effective surveillance during and after treatment is especially important. It is essential that bladder cancers, whether primary or recurring, are diagnosed quickly and correctly to ensure the correct magnitude of treatment is provided, proportional to the severity of the tumour. A delay of just a few months can severely impact patient survival.\r\n\r\nCurrently, the best practices for diagnosing bladder cancer rely on cystoscopy and cytology. Determining the severity of bladder cancer is particularly challenging though, as distinguishing between urothelial tumour stages is not always possible with conventional imaging techniques. Earlier stage aggressive carcinomas may be often undistinguishable from advanced deeply penetrating tumours from the surface view. Indeed, the plain stage of bladder cancer (CIS), which is often particularly aggressive if left alone, can go unseen entirely with traditional white light endoscopy.\r\n\r\nThe Amplitude project (Advanced Multimodal Photonics Laser Imaging Tool for Urothelial Diagnosis in Endoscopy) began in January 2020, with the aims to develop new, advanced multi-modal imagining tools to diagnose bladder cancer faster and more accurately. The stand-out feature of Amplitude is the ability to view far deeper into tissue than traditional spectroscopy tools. Current imaging tools use light wavelengths less than 1350nm to target two distinct \u2018biological windows\u2019, which penetrate only a short distance through tissue. Hence the difficulty distinguishing bladder cancer stages.\r\n\r\nEnabled by novel laser technologies and expertise, Amplitude will target the third biological window, covering wavelengths between 1550-1870nm. In this window, light can penetrate deeper into tissue at high resolution. By viewing this deep into tissue, cancer staging will be far less ambiguous, improving the speed and accuracy of diagnosis. However, this window is currently only accessible using broad-application supercontinuum lasers, which are far beyond the budget and requirements for biomedical imaging. Amplitude is instead developing fibre lasers designed specifically to access the third biological window in an affordable and compact package, bringing the technology to the clinic and the patients.\r\n\r\nThe earlier patients are diagnosed with cancer, the better their chance of survival, the less severe the treatment, and the lower the impact on their quality of life. Equally as important though is correct diagnosis, as cancer treatments are far too harsh to make light of false positives, and the consequences too severe to allow for false negatives. Amplitude aims to develop the tools necessary to ensure that these diagnoses are as rapid and accurate as possible, to protect as many cancer patients as possible. New advanced technologies and world leading multidisciplinary expertise grants Amplitude the potential to revolutionise the cancer diagnostics landscape.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n  ","username":"n0033x19","keywords":"Bladder Cancer, Photonics, Microscopy, Endoscopy, Diagnostics, Clinical, Cytoscopy, Multi Modal Imaging System","contentCreationDate":"2021-01-21 11:10:42","contentUpdateDate":"2021-01-21 11:10:24","lastUpdateDate":"2026-01-06 15:22:18","archivedDate":"2024-03-25 00:00:00","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"indust","title":"Industrial Technologies","displayCode":"\/Industrial Technologies","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"health","title":"Health","displayCode":"\/Health","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"news","title":"News","description":"Article: news","displayCode":"\/News","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"newProducts","title":"New products and technologies","displayCode":"\/New products and technologies","attributes":{"classification":"nature","type":"groupedBy"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"wire","title":"Wire","description":"WIRE is available for all registered users who can submit their own content","displayCode":"\/Wire","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"en","rcn":"1968613","legalName":"Modus Research and Innovation","address":{"street":"Dundee Technology Park","city":"Dundee","postalCode":"DD2 1TY","country":"UK","url":"https:\/\/modus.ltd\/"},"relations":{"regions":[{"name":"United Kingdom","rcn":"508725800","nutsCode":"UK","euCode":"UK","isoCode":"GB","attributes":{"type":"relatedRegion"}}]},"contenttype":"organization","attributes":{"source":"wire","type":"relatedOrganization"}},{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664086","code":"H2020","frameworkProgramme":"H2020","contenttype":"programme","attributes":{"source":"wire","type":"relatedProgramme"}},{"availableLanguages":"en","rcn":"226497","id":"871277","acronym":"AMPLITUDE","teaser":"There is an absence of lasers with the necessary wavelengths and characteristics to access the possibilities for deeper high-resolution biological tissue imaging in the third bio-window between 1650 nm and 1870 nm. Motivated by recent breakthrough results in multi-photon...","title":"Advanced Multimodal Photonics Laser Imaging Tool for Urothelial Diagnosis in Endoscopy","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/251\/48354418","title":"microscopy","displayCode":"\/natural sciences\/physical sciences\/optics\/microscopy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/21\/39\/225","title":"oncology","displayCode":"\/medical and health sciences\/clinical medicine\/oncology","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/251\/745","title":"laser physics","displayCode":"\/natural sciences\/physical sciences\/optics\/laser physics","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/43\/251\/1077","title":"spectroscopy","displayCode":"\/natural sciences\/physical sciences\/optics\/spectroscopy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"RIA","title":"Research and Innovation action","description":"Research and Innovation action","displayCode":"\/Research and Innovation action","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664147","code":"H2020-EU.2.1.1.","frameworkProgramme":"H2020","pga":"H2020-EU.2.1.1.","title":"INDUSTRIAL LEADERSHIP - Leadership in enabling and industrial technologies - Information and Communication Technologies (ICT)","shortTitle":"Information and Communication Technologies","parent":{"rcn":"664145\/664143\/664087\/664086","code":"H2020-EU.2.1.\/H2020-EU.2.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"en","rcn":"703859","code":"ICT-05-2019","frameworkProgramme":"H2020","title":"Application driven Photonics components","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}},{"language":"en","code":"31050711","title":"Diagnostics","displayCode":"\/Diagnostics","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31053855","title":"Photonic integration, photonic integrated circuits","displayCode":"\/Photonic integration, photonic integrated circuits","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31053845","title":"Manufacturing technologies for photonic devices","displayCode":"\/Manufacturing technologies for photonic devices","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31053853","title":"Photonic devices","displayCode":"\/Photonic devices","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31053854","title":"Photonics in computing, interconnects, data storage","displayCode":"\/Photonics in computing, interconnects, data storage","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31053958","title":"Biophotonics, Imaging, image and data processing","displayCode":"\/Biophotonics, Imaging, image and data processing","attributes":{"classification":"topicKeyword","type":"isAbout"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"wire","type":"relatedProject"}},{"language":"en","availableLanguages":"en,any","uri":"\/docs\/wire\/images\/2021-01\/20210120-112247171.png","mimetype":"image\/png","size":"62943","copyright":"\u00a9      Amplitude","contenttype":"webItem","attributes":{"represents":"article","source":"wire","type":"relatedImage"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}