{"contenttype":"article","language":"en","availableLanguages":"de,en,es,fr,it,pl","rcn":"453215","id":"453215-switching-between-fuel-sources-gives-constant-supply-of-green-energy","title":"Switching between fuel sources gives a constant supply of green energy","teaser":"An innovative system that can switch between different fuel sources, including renewable energy and biomethane, can maintain a stable supply of green hydrogen.","body":"\r\n    \u003Csection\u003E\r\n      \u003CsectionBody\u003EA system that switches between fuel sources can ensure a stable supply of low-carbon hydrogen-based electricity, such as for transport refuelling stations. \r\n\r\n\u201cWe used solid oxide [cell] technologies to develop the system to produce hydrogen by multifuel. This means the same system can be fed by electrical power, renewable power and water electrolysis processes, switching between them as necessary,\u201d explains project coordinator Matteo Testi. He heads the Hydrogen Technologies and Resilient Energy Systems (HyRES) unit at the https:\/\/www.fbk.eu\/en\/ (Bruno Kessler Foundation) in Italy. \r\n\r\nHigh-quality heat from the fuel cell is used to generate hydrogen efficiently. \u201cThe prototype can split water to produce oxygen and hydrogen with high purity. But if we don\u2019t have renewable energy, it can switch to electrolysis to convert biomethane to produce hydrogen as electrical power,\u201d he adds.\r\n\r\nThe https:\/\/switch-fch.eu\/ (SWITCH) system builds on an earlier EU-funded project. Called https:\/\/cordis.europa.eu\/project\/id\/735692 (CH2P), it developed a prototype to produce hydrogen from biomethane using a solid oxide fuel cell (SOFC). \r\n\r\nTesti and his team wanted to expand the functionality to include electrolysis and to use different types of energy input.\r\n\r\n\u201cThis is easy enough to say, but to produce hydrogen by these two input methods means two totally different processes. From an engineering point of view, it requires different components and system design to reduce energy wastage from switching,\u201d he says.\r\n\r\nThe challenge during the design phase was finding a minimum number of components that could work with both processes.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n    \u003Csection\u003E\r\n      \u003CsectionTitle\u003EDetecting energy input and adjusting processes\u003C\/sectionTitle\u003E\r\n      \u003CsectionBody\u003EA unique control system developed by the project partners detects the type of energy input and seamlessly adjusts the processes. This includes using electrolysis to produce hydrogen from renewable electricity or steam cracking for biomethane. \r\n\r\n\u201cThere are standards, codes of conduct and regulations to respect, so it took a lot of time to produce a robust, standardised control for the multiple cell stack, while integrating safety functions,\u201d he adds.\r\n\r\n\u201cEnsuring robust safety and control systems were properly developed and validated was critical for a high-power hydrogen production system.\u201d \r\n\r\nThe control system went through several prototypes, integrating safety systems and protocols to handle operating conditions and risks associated with each process.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n    \u003Csection\u003E\r\n      \u003CsectionTitle\u003ETesting for safety and robustness\u003C\/sectionTitle\u003E\r\n      \u003CsectionBody\u003EOptimising efficiency and performance, especially in switching between energy input modes, required extensive testing and refinement to get to a prototype that could be demonstrated in an operational environment.\r\n\r\n\u201cWe faced several problems because the methodology was to validate each component individually \u2013 the cell, data changer, the steamer, the reactor. We integrated them based on a simulation design which saves time and money. It was assembled in two containers in the demo site run by https:\/\/hygear.com\/ (HyGear) in the Netherlands,\u201d he notes, referring to the hydrogen technology consortium partner. \r\n\r\nDespite disruption caused by the COVID-19 pandemic during the demonstration period, the prototype was tested for 1 000 hours in the solid oxide electrolyser (electrolysis) mode, to check for degradation in the cell stack. \r\n\r\n\u201cWe saw no trace of degradation. This is important because the system is complex and impurities can come in from different points,\u201d according to Testi.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n    \u003Csection\u003E\r\n      \u003CsectionTitle\u003EModular system tailored to energy applications\u003C\/sectionTitle\u003E\r\n      \u003CsectionBody\u003EThe prototype was designed as a modular system. Hydrogen production can be scaled up or down by adding or removing modular components such as the fuel cell stacks and associated subsystems. \r\n\r\n\u201cIt allows the system to be tailored to the specific needs and energy sources available at a given location or application,\u201d Testi says.\u003C\/sectionBody\u003E\r\n    \u003C\/section\u003E\r\n  ","keywords":"SWITCH, energy, renewable energy, hydrogen, methane, biomethane, solid oxide fuel cell, SOFC, CH2P, electrolysis, HyGear","contentCreationDate":"2024-08-26 09:28:09","contentUpdateDate":"2024-08-26 09:28:00","lastUpdateDate":"2024-11-13 13:58:46","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"ener","title":"Energy","displayCode":"\/Energy","attributes":{"classification":"applicationDomain","type":"isApplicableIn"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"brief","title":"Result in Brief","description":"Article: Classic and enhanced","displayCode":"\/Result in Brief","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"fr","rcn":"3764817","id":"edit-sharmyo","contenttype":"person","attributes":{"source":"editorial","type":"isWrittenBy"}},{"availableLanguages":"en","rcn":"226557","id":"875148","acronym":"SWITCH","teaser":"Solid Oxide Cells are efficient ways to convert variable electricity from renewables in green hydrogen. At the same time, they can be used in a reversible mode to enable the use of other sources (e.g. methane, bio-methane) to match a variable energy production with continuous...","title":"SMART WAYS FOR IN-SITU TOTALLY INTEGRATED AND CONTINUOUS MULTISOURCE GENERATION OF HYDROGEN","relations":{"categories":[{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"project","title":"Project","description":"Project factsheets","displayCode":"\/Project","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/23\/53\/363\/1099","title":"aliphatic compounds","displayCode":"\/natural sciences\/chemical sciences\/organic chemistry\/aliphatic compounds","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1173","title":"fuel cells","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/fuel cells","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"\/25\/67\/425\/1169\/1691","title":"hydrogen energy","displayCode":"\/engineering and technology\/environmental engineering\/energy and fuels\/renewable energy\/hydrogen energy","attributes":{"classification":"euroSciVoc","type":"isInFieldOfScience"}},{"language":"en","availableLanguages":"en","code":"IA","title":"Innovation action","description":"Innovation action","displayCode":"\/Innovation action","attributes":{"classification":"projectFundingSchemeCategory","type":"relatedProjectFundingSchemeCategory"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}}],"associations":[{"availableLanguages":"de,en,es,fr,it,pl","rcn":"664321","code":"H2020-EU.3.3.","frameworkProgramme":"H2020","pga":"H2020-EU.3.3.","title":"SOCIETAL CHALLENGES - Secure, clean and efficient energy","shortTitle":"Energy","parent":{"rcn":"664235\/664087\/664086","code":"H2020-EU.3.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis","uniqueProgrammePart":"true"}},{"availableLanguages":"en","rcn":"665337","code":"H2020-EU.3.3.8.2.","frameworkProgramme":"H2020","pga":"H2020-EU.3.3.8.2.","title":"Increase the energy efficiency of production of hydrogen mainly from water electrolysis and renewable sources while reducing operating and capital costs, so that the combined system of the hydrogen production and the conversion using the fuel cell system can compete with the alternatives for electricity production available on the market","parent":{"rcn":"665333\/664321\/664235\/664087\/664086","code":"H2020-EU.3.3.8.\/H2020-EU.3.3.\/H2020-EU.3.\/H2020-EC\/H2020"},"relations":{"categories":[{"language":"en","code":"legalbasis","title":"Legal Basis","description":"Programme: Legal basis for research funding","displayCode":"\/Legal Basis","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"editorial","title":"CORDIS Editorial","description":"Written by CORDIS","displayCode":"\/CORDIS Editorial","attributes":{"classification":"source","type":"isProvidedBy"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedLegalBasis"}},{"availableLanguages":"en","rcn":"704070","code":"FCH-02-3-2019","frameworkProgramme":"H2020","title":"Continuous supply of green or low carbon H2 and CHP via Solid Oxide Cell based Polygeneration","parent":{"rcn":"20200","code":"H2020-Topics"},"relations":{"categories":[{"language":"en","code":"topic","title":"Topic","description":"Programme: Part of the Commission work programme implementing legal basis","displayCode":"\/Topic","attributes":{"classification":"collection","type":"belongsTo"}},{"language":"en","code":"corda","title":"CORDA","description":"RTD research data warehouse","displayCode":"\/CORDA","attributes":{"classification":"source","type":"isProvidedBy"}},{"language":"en","code":"31049287","title":"Combined Heat \u0026 Power","displayCode":"\/Combined Heat \u0026 Power","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31049223","title":"Energy efficient buildings","displayCode":"\/Energy efficient buildings","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31049288","title":"Renewable Energy CHP","displayCode":"\/Renewable Energy CHP","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31051378","title":"Renewable energy sources","displayCode":"\/Renewable energy sources","attributes":{"classification":"topicKeyword","type":"isAbout"}},{"language":"en","code":"31049290","title":"Renewable energy sources - general","displayCode":"\/Renewable energy sources - general","attributes":{"classification":"topicKeyword","type":"isAbout"}}]},"contenttype":"programme","attributes":{"source":"corda","type":"relatedTopic"}}]},"contenttype":"project","attributes":{"source":"editorial","type":"relatedProject"}},{"language":"en","availableLanguages":"de,en,es,fr,it,pl,any","uri":"\/docs\/article\/images\/2024-08\/453215.jpg","mimetype":"image\/jpeg","size":"153341","copyright":"\u00a9 adobedesigner \/stock.adobe.com","contenttype":"webItem","attributes":{"represents":"article","source":"editorial","type":"relatedImage"}}],"regions":[{"name":"Italy","rcn":"309758504","nutsCode":"IT","euCode":"IT","isoCode":"IT","attributes":{"source":"editorial","type":"relatedRegion"}}]},"modelVersion":"132","icaVersion":"20.0.0-48f81e07"}